6.2.5.
Assignment of commands to the keys and the control inputs
Command Setting
Range
Default
Key Up Func. (additional function of the UP key)
0 … 8
0
0
no command assigned
For more details
about the function of
these commands
please refer to
chapter 7.
1
Send Data
2
Disable Output
3
Freeze Output
4
Direction
5
Reference Z
6
Reset
7
Trim -
8
Trim +
Key Down Func. (similar to Key UP, but additional function of the Down key)
0 … 8
0
Key Enter Func. (similar to Key UP, but additional function of the Enter key)
0 … 8
0
Input 1 Config. (Switching characteristics of Input "Cont.1")
0 … 1
0
0
Static Low
1
Static High
Input 1 Func. (control function of input „Cont.1“)
0 … 9
0
0
no command assigned
For more details
about the function of
these commands
please refer to
chapter 7.
1
Send Data
2
Disable Output
3
Freeze Output
4
Direction
5
Reference Z
6
Reset
7
Trim -
8
Trim +
9
Key Lock
Input 2 Config. (see Input 1 Config. but "Cont.2")
0 … 1
0
Input 2 Func.
(see Input 1 Func. but "Cont.2")
0 … 9
Input 3 Config. (see Input 1 Config. but "Cont.3")
0 … 1
0
Input 3 Func.
(see Input 1 Func. but "Cont.3")
0 … 9
Input 4 Config. (see Input 1 Config. but "Cont.4")
0 … 1
0
Input 4 Func.
(see Input 1 Func. but "Cont.4")
0 … 9
0
When any of the control inputs (Cont.1 – Cont.4) is used for referencing of the marker pulse
(Parameter „Input Z Config“
≠
0, see 6.2.2), no further assignment of a command will be
allowed to this input (i.e. Input X Func. must be 0)