*) With settings HTL / NPN the input terminals are connected to the power supply voltage
of the unit (+24V) via internal pull-up resistors. For this reason it is advisable to first set the
encoder properties correctly, prior to connecting TTL encoders to the unit.
Setting HTL / NPN is also suitable for use with NAMUR (2-wire) proximities.
(connect the positive wire of the sensor to the input terminal and the negative wire to GND))
6.2.3.
Display settings
Display Settings
Range
Default
Up-Date-Time
Update time of the LCD display (sec.)
0.05 … 1.00
0.25
Display Mode
Scaling of the actual conversion error shown on the LCD display *)
0 … 3
0
0
Number of impulses that output lags input, format X.XXXX inc.
1
Number of impulses that output lags input, format XXXXX inc.
2
Conversion error converted to angular degrees, format X.XX °
Parameter „Display Factor“ must be set to the appropriate number of
ppr for this
3
Error display according to user scaling, format XXXX units.
tor
DisplayFac
ti
DisplayMul
Error
Display
.
Display Factor
Parameter for error scaling with modes 2 + 3
1 ... 99,999
100
Display Multi.
Parameter for error scaling with mode 3
1 ... 999
100
Inhibit Overflow
Sets the display mode of an overflow message
0 … 2
0
0
„Overflow“ is latched in display until cleared by a Reset command
1
„Overflow“ is displayed while an overflow situation exists and
disappears automatically after catch-up of the error
2
No overflow message will appear
6.2.4.
Keypad access protection by password
Key-Pad Settings (Code for the corresponding menu)
Range
Default
Protect Menu 01 (Factor Settings)
0 = no password
protection
1 … 999.999 =
password for the
corresponding menu
0
Protect Menu 02 (General Settings)
0
Protect Menu 03 (Display Settings)
0
Protect Menu 04 (Key-Pad Settings)
0
Protect Menu 05 (Command Settings)
0
Protect Menu 06 (Serial Settings)
0
*) The conversion error indicates by how many impulses the output actually lags the input. Since in general any
lagging error will be compensated within microseconds only, the display of conversion error and overflow
message are only of interest under special conditions.