CT70104B_e.doc / Nov-15
Page 15 / 29
4.3.5.
Jog/Home
This register card specifies the Jog and Homing functions:
Jog Speed
Jog speed for manual movement of the cutter drive
Jog Ramp
Ramp time for acceleration and deceleration when using the Jog function
Home Speed Hi
Fast Homing speed.
Every homing cycle will start with this speed.
Home Speed Lo
Slow Homing speed.
A Homing cycle will end with this speed
Home Ramp
Ramp time for acceleration and deceleration with Homing cycles
Home Switchpnt
Distance from the final home position (scaled in length units) where the
homing speed changes over from high speed to low speed.
4.3.6.
Alarms
Settings for monitoring functions:
Min. Master
Frequency
When the real master encoder frequency becomes lower than this set
value, the unit substitutes the encoder frequency by this setting. This
prevents the shear from stopping while the tool is penetrated to the
material.
Max. Analogue
Output
When the analogue speed output signal gets higher than this setting, the
“Speed too High” output signal will switch on.
4.3.7.
Diagnosis
Settings for diagnosis functions:
Sel. Diag.
Ana Out 1
Selects the actual value (Process Data) that is put out at analogue output
“Ana Out 1”.
The gain of the analogue diagnosis signal is set by parameter “Ana Out 1
Gain”. When set to 10.00, an actual value of 2048 is repre-sented by an
analogue output voltage of 10 V.
4.3.8.
Communication settings
This register card sets the communication parameters for the CAN interface and the serial link.
Settings and operation of the CANopen interface are explained separately in the manual CI700,
which is available on our homepage or on our CD-ROM
The serial link uses the following parameters: