17
6 ON
“Maintained Action”, gate operation
keeping the pushbutton pressed;
this
function excludes use of the remote control;
7 OFF
Re-opening during closure (only
with photoelectric cells connected,
otherwise leave the dip set to ON).
If an obstacle is detected during closure,
the gate reverses direction to reach full-
open position;
a)
b)
a)
b)
c)
8 OFF
Partial stop (only with photoelectric
cells connected, otherwise leave the dip
set to ON).
If an obstacle is detected during movement,
the gate stops.
N.B.: with the automatic-closing function
on (dip 1 ON), the gate closes auto-
matically
ref. c)
, or use the transmitter or
pushbutton;
9 ON
Photoelectric cell test;
at every gate
opening and closure command, the con-
trol unit checks the efficiency of the photo-
electric cells (
see page 15
);
10
Not used, keep the dip switch in its OFF
position.
Opening
Closure
12
6
3
9
1
2
4
5
7
8
10
11
0"
90"
2
1
3
4
5
6
7
8
9 10
ON
1
a
pair of photoelectric cells (external)
2
a
pair of photoelectric cells (internal)