CSD Series
Variable Frequency AC Drive
MOTORTRONICS
- 52 -
Fn123 = 1111: Revert to Factory Setting
The parameters of the drive can be set back to factory settings (with
the exception of Fn0, 5, 6, 30, 100-106, 124) by programming Fn123
= 1111.
Fn124 = CPU Version
The CPU version is factory set.
Do not change this information.
Fn125 = Fault Sequence Reference
To assist in troubleshooting, the drive remembers the last three fault
codes automatically in its EEPROM memory. Once in Fn125,
depressing the increase (
∆
) and decrease (
∇
) keys on the keypad will
display the last three faults recorded. Refer to the fault code indication
in this manual for an explanation of possible causes of these faults
and possible solutions.
Summary of Contents for CSD Series
Page 2: ...CSD Series Variable Frequency AC Drive MOTORTRONICS 74 ...
Page 4: ...CSD Series Variable Frequency AC Drive MOTORTRONICS 76 ...
Page 30: ...CSD Series Variable Frequency AC Drive MOTORTRONICS 26 ...
Page 32: ...CSD Series Variable Frequency AC Drive MOTORTRONICS 28 ...
Page 65: ...CSD Series Variable Frequency AC Drive MOTORTRONICS 61 ...