Administrator Console 3 - 39
Combined mode with LIB
When read points are combined or not configured to type area, the LMS triggers reads from antennas 1,2, (5 and 6
for XR480) and the RMS triggers antennas 3,4, (7 and 8 for XR480)
Typically, when the combined antenna configuration is used, the reads are triggered from the motion sensor of the
lowest indexed read point in the combined group. For example, if combined group 1 combines read points 1 and 3,
the reads in both antennas happen when the LMS from read point 1 is triggered.
The left yellow LED interfaced over Motorola LIB is ON when the LMS triggers antennas 1,2 (5,6) and they are
reading tags. Similarly, right yellow LED on Motorola LIB is ON when the RMS triggers antennas 3,4 (7,8) and they
are reading tags.