GPRS Tri Band T260 Level 3 procedure Rev.1
mercoledì, gennaio 24, 2001
- MOTOROLA Level3 Authorized -
T260:
NO
CHARGER
Is thermistor problem ?
(check it using gate22
processing test)
START
Is there 2,7Volt on
BATT_THERM
terminal on pin 2 of
J604 ?
Check Q914,U905 and
relative discrete
componets NOTE1 or
Faulty.
Without battery, Is there
2,7Volt on pin1 of U905 ?
(with battery it must be
0Volt).
Check U905 and Q908
NOTE1 or Faulty.
Check U800 NOTE1 or
Faulty.
Put the phone in
test mode and digit
500255#
Is there on pin3 of Q900
about EXT_B+ voltage ?
Check R913
Is there 0Volt on pin4 of
Q900 ?
Check U900 NOTE1 or
Faulty.
Is there about EXT_B+
voltage on pin4 of J604
Check Q900 NOTE1 or
Faulty and J604
NOTE1.
Check Q900 NOTE1 or
Faulty
NO
NO
NO
NO
NO
NO
YES
YES
YES
YES
YES
YES
NOTE1 : check if any components mentioned are
correctly positioned , have not dry joint and aren't
not phisically damaged .
pag.22