GPRS Tri Band T260 Level 3 procedure Rev.1
mercoledì, gennaio 24, 2001
- MOTOROLA Level3 Authorized -
T260:
NO ALERT/LOUDSPEAKER
START
Insert the correct Software
and Flex File then make reset
572#
If still NOT Work correctly
Check U900 and U800
NOTE1 or faulty.
Is Ringer and
Loudspeaker
problem ?
Put PCB in test mode and digit
432#, 1559#, 4707#
Put PCB in test mode and
digit 481000#, 434#, 4707#
Are present on
Terminal SPKR+
and SPKR- the 1Khz
( about 0,5 V P/P,
1,5V offset ) ?
Check U900,CR911 and the
discrete components from
U900 to Loudspeaker
terminals (C969, etc.)
NOTE1 or Faulty
Check for
intermittent
problem.
It is only internal Loudsp. problem.
It is only Ringer problem.
Is present on Pins
5/6 of Q903 about 3V
?
Insert the correct Software
and Flex File then make
reset 572#
If still NOT Work
correctly continue.
Check the presence of B+ on Pin4
of Q903.
If OK check Q903,VR900/1
NOTE1 or Faulty.
YES
YES
YES
NO
NO
NO
Is present on Pin
ALRT_OUT of Alert
terminal the Ring
signal ?
Check U900 and VR901
NOTE1 or Faulty.
Check If it is an
intermittent problem.
NO
YES
NOTE1 : check if any components mentioned are
correctly positioned , have not dry joint and aren't
not phisically damaged .
Is present the
"accessory Setup"
on customer menu
?
YES
NO
A
on pg.16
pag.15