User Guide: PTP 800 Licensed Ethernet Microwave
Recovering the CMU
phn-1478_005v000
Apr 2010
7-17
Figure 7-4 Recovery Software Upgrade complete page
Resetting IP and Ethernet configuration to factory defaults
Perform this task when the CMU is in recovery mode. The purpose of this task is to
reset IP and Ethernet configuration back to factory defaults.
Before starting this task, check that the Recovery Options page is displayed (
Figure
7-2
).
To reset IP and Ethernet configuration parameters, proceed as follows:
Procedure 7-4 Reset IP and Ethernet configuration in recovery mode
1
Select
Reset IP & Ethernet Configuration back to factory defaults
. The
Reset Configuration dialog is displayed (
Figure 7-5
).
2
Select
OK
. The Recovery Options page is redisplayed with a message
indicating that the configuration has been reset.
3
Select
Reboot
. The Reboot Confirmation dialog is displayed (
Figure 6-14
).
4
Select
OK
. The reboot progress message is displayed. On completion, the
CMU restarts.
5
To restore the IP and Ethernet configuration to meet the operator’s
requirements, see
Configuring the IP and Ethernet interfaces
on page
6-18.
NOTE
When the CMU is rebooted after selecting the recovery option
Reset IP
& Ethernet Configuration back to factory defaults
, the IP address
remains at its default setting of 169.254.1.1 and the CMU can only be
accessed via a direct network connection from the PC to the management
port.
Summary of Contents for PTP 800
Page 22: ...List of Tables phn 1478_005v000 xx Apr 2010 ...
Page 72: ...System management Chapter 1 Product description phn 1478_005v000 1 38 Apr 2010 ...
Page 290: ...Alternative approaches Chapter 5 Installation phn 1478_005v000 5 116 Apr 2010 ...
Page 354: ...Managing performance Chapter 6 Operation phn 1478_005v000 6 64 Apr 2010 ...