User Guide: PTP 800 Licensed Ethernet Microwave
ODU specifications
phn-1478_005v000
Apr 2010
4-11
ODU specifications (26 GHz)
Motorola can supply the ODUs listed in
Table 4-11
for PTP 800 links that will
operate in the 26 GHz band (frequency range 24.25 - 26.50 GHz).
Table 4-11 ODU specifications – main frequency 26 GHz
Motorola
Part
Number
Standard
Sub-
band
Sub-band
frequency
Transmit
and
receive
spacing
01010403003
B1-Lo
24549 – 24885 MHz
01010403004
B1-Hi
25557 – 25893 MHz
01010403005
B2-Lo
24829 – 25165 MHz
01010403006
B2-Hi
25837 – 26173 MHz
01010403007
B3-Lo
25109 – 25445 MHz
01010403008
ETSI
B3-Hi
26117 – 26453 MHz
1008
MHz
ODU specifications (38 GHz)
Motorola can supply the ODUs listed in
Table 4-12
for PTP 800 links that will
operate in the 38 GHz band (frequency range 37 - 39.5 GHz).
Table 4-12 ODU specifications – main frequency 38 GHz
Motorola
Part
Number
Standard
Sub-
band
Sub-band
frequency
Transmit
and
receive
spacing
01010433002 B1-Lo
38595
– 38805 MHz
01010433003
B1-Hi
39295 – 39505 MHz
01010433004
B2-Lo
38795 – 39005 MHz
01010433005
B2-Hi
39495 – 39705 MHz
01010433006
B3-Lo
38995 – 39205 MHz
01010433007
B3-Hi
39695 – 39905 MHz
01010433008
B4-Lo
39195 – 39405 MHz
01010433009
FCC
B4-Hi
39895 – 40105 MHz
700 MHz
Summary of Contents for PTP 800
Page 22: ...List of Tables phn 1478_005v000 xx Apr 2010 ...
Page 72: ...System management Chapter 1 Product description phn 1478_005v000 1 38 Apr 2010 ...
Page 290: ...Alternative approaches Chapter 5 Installation phn 1478_005v000 5 116 Apr 2010 ...
Page 354: ...Managing performance Chapter 6 Operation phn 1478_005v000 6 64 Apr 2010 ...