Modifying the Environment
6-13
6
Note
LED/Serial Startup Diagnostic Codes: these codes can
be displayed at key points in the initialization of the
hardware devices. Should the debugger fail to come up
to a prompt, the last code displayed will indicate how
far the initialization sequence had progressed before
stalling. The codes are enabled by an
ENV
parameter:
Serial Startup Code Master Enable [Y/N]=N?
A line feed can be inserted after each code is displayed to
prevent it from being overwritten by the next code. This is also
enabled by an
ENV
parameter:
Serial Startup Code LF Enable [Y/N]=N?
The list of LED/serial codes is included in the section on
MPU,
Hardware, and Firmware Initialization
in Chapter 1 of the
PPCBug
Firmware Package UserÕs Manual
.
Configuring the VMEbus Interface
ENV
asks the following series of questions to set up the VMEbus
interface for the MVME230x modules. To perform this
configuration, you should have a working knowledge of the
Universe ASIC as described in your
MVME2300-Series VME
Processor Module ProgrammerÕs Reference Guide
.
VME3PCI Master Master Enable [Y/N] = Y?
PCI Slave Image 0 Control = 00000000?
The conÞgured value is written into the LSI0_CTL register of
the Universe chip.
PCI Slave Image 0 Base Address Register = 00000000?
The conÞgured value is written into the LSI0_BS register of the
Universe chip.
Y
Set up and enable the VMEbus Interface.
(Default)
N
Do not set up or enable the VMEbus Interface.
Summary of Contents for MVME2301
Page 1: ...MVME2300 Series VME Processor Module Installation and Use V2300A IH2 ...
Page 8: ......
Page 14: ...xiv ...
Page 48: ...Operating Instructions 2 8 2 ...
Page 80: ...Programming the MVME230x 4 12 4 ...
Page 92: ...Using PPCBug 5 12 5 ...
Page 110: ...ENV Set Environment 6 18 6 ...
Page 118: ...Ordering Related Documentation A 8 A ...