Hardware Preparation and Installation
1-33
1
PM603/604 Processor/Memory Mezzanine
To install a PM603 or PM604 processor/memory mezzanine on an
MVME1603/1604 main module, refer to Figure 1-10 and proceed as
follows:
1. Attach an ESD strap to your wrist. Attach the other end of the ESD
strap to the chassis as a ground. The ESD strap must be secured to
your wrist and to ground throughout the procedure.
2. Perform an operating system shutdown. Turn the AC or DC power
off and remove the AC cord or DC power lines from the system.
Remove chassis or system cover(s) as necessary for access to the
VMEmodules.
!
Caution
Inserting or removing modules with power applied may result
in damage to module components.
!
Warning
Dangerous voltages, capable of causing death, are present in
this equipment. Use extreme caution when handling, testing,
and adjusting.
3. Carefully remove the MVME1603/1604 from its VMEbus card slot
and lay it flat, with connectors P1 and P2 (the rear panel) facing you.
!
Caution
Avoid touching areas of integrated circuitry; static discharge
can damage these circuits
!
Caution
The 192MB module is a factory-installed option. It is
recommended that you do not attempt to remove it, as the
components could easily be damaged.
4. Place the PM603 or PM604 mezzanine module on top of the
MVME1603/1604, with the cutout corner at the upper right.
Connector J5 at the bottom edge of the PM603 or PM604 should
connect smoothly with its corresponding connector on the
MVME1603/1604.