Maintenance
6 - 27
12. Remove the main PCB from the Handset back housing by unfastenning the four self tapping
screws using a T7 TORX™ screw bit.
13. Unplug the earpiece and microphone wire to board connectors from the Handset main PCB.
Remove the Handset main PCB from the Handset back housing.
Figure 6-31
Main PCB Removal from Handset Back Housing
14. Unplug the micro-USB BTB connector from the keypad flex.
15. Remove the two screws from the Handset front housing using a T6 TORX™ screw bit and
remove the micro-USB module from the Handset front housing.
Figure 6-32
Micro-USB Module Removal
16. Remove the spiral cord retainer from the Handset front housing.
17. Remove the keypad retainer by stretching the Handset front housing outwards as shown in
Figure 6-33
Keypad Retainer Removal
ZWG0130215-O
Self tapping
screws
Micro-USB module
ZWG013021 O
Pry the front housing outwards
for both sides to remove the keypad
retainer
Summary of Contents for MTM800 FuG ET