![Motorola MTM800 FuG ET Basic Service Manual Download Page 39](http://html.mh-extra.com/html/motorola/mtm800-fug-et/mtm800-fug-et_basic-service-manual_244729039.webp)
Test Setup & Testing for 380–430 MHz
5.1 - 1
CHAPTER 5.1
TEST SETUP & TESTING FOR 380–430 MHZ
Typical Test Setup
Before Testing
Carry out the following instructions before testing:
•
Connect the DC cable to the DC connector on the terminal.
•
Connect the other side of the DC cable to the DC output connector on the power supply
•
Connect an RF cable to the N-type RF Connector of the IFR.
•
Connect the other side of the RF cable to the antenna connector on the terminal.
•
Set the DC voltage on the power supply to 13.2 Volts.
•
Switch on the terminal.
Figure 5.1-1
Typical Test Setup
Any level 3 repairs can deeply affect the performance of the
MTM5400/MTM800 FuG with Enhanced Control Head terminal and may
cause a new tuning procedure.
This tuning procedure can only be applied by certain authorized Motorola
depots where the appropriate TEST&TUNE EQUIPMENT is available.
The appropriate TEST&TUNE EQUIPMENT is a special automated test
equipment which is only available at some Motorola factories and Motorola
repair centers.
!
W A R N I N G
!
CCCCC
CC
CC
CC
CCCCCCCC
CCC
CC
C
C
C
C
C
CC
C CC
CC
CC
C
IFR2968
N-Type
RF Connector
RF-Cable
Speaker
Microphone
Power Supply
13.2V 5A
DC Cable
BNC-Type
RF Connector
Summary of Contents for MTM800 FuG ET
Page 2: ......
Page 6: ...vi COPYRIGHT Notes ...
Page 8: ...viii DOCUMENT HISTORY Notes ...
Page 16: ...xvi Product Safety and RF Exposure Notes ...
Page 32: ...2 8 Model Information Accessories Notes ...
Page 36: ...4 2 Programming the Terminal Notes ...
Page 38: ...5 2 Test Setup Testing Notes ...
Page 56: ...5 1 18 Test Setup Testing for 380 430 MHz Notes ...
Page 116: ...A 10 Replacement Parts Kits Notes ...
Page 119: ......