5.1 - 2
Test Setup & Testing for 380–430 MHz
Test Equipment
The table below lists the special test equipment required for servicing TETRA mobile terminals.
Test Check List
The following table summarises the required test setups.
Table 5.1-1
Test Equipment
Name
Part Number
Digital Multimeter
R1072_
220V Power Supply
R1011_/220V
TETRA SVC MON. MOBILES ONLY
WADN4161A
TETRA SVC MON. MOB.+ DIR.MODE
WADN4163A
TETRA SVC MON. MOB.+ BASE ST.
WADN4164A
TETRA SVC MON. MOB.+ BASE ST. + DIRECT MODE
WADN4173A
TETRA SVC MON. MOB.+ DIR.MODE + MPT1327/1343
WADN4233A
Table 5.1-2
Test Setup
No.
Test Name
Test Setup
Terminal Setup
Test Conditions
Limits
1.
IFR System Setup
and Manual Test
Screen
Control Channel
For 380–430 MHz
terminal: 3605
Traffic Channel
For 380–430 MHz
terminal: 3605
Time Slot
3
Country Code
234
Network Code
2392
Base Color
1
Location Area
224
Min Rx Level
-110dBm
Max Tx Level
40dBm (10W)
Access
Parameter
-33dBm
Mobile Power
40dBm (10W)
Burst Type
Normal
2.
Base Station
Registration
RF Gen Level
For 380–430 MHz
terminal: 390.125 MHz
-90dBm
3.
Receiver RSSI
RF Gen Level
Cells Info
RSSI
TRACE
-90dBm
Summary of Contents for MTM800 FuG ET
Page 2: ......
Page 6: ...vi COPYRIGHT Notes ...
Page 8: ...viii DOCUMENT HISTORY Notes ...
Page 16: ...xvi Product Safety and RF Exposure Notes ...
Page 32: ...2 8 Model Information Accessories Notes ...
Page 36: ...4 2 Programming the Terminal Notes ...
Page 38: ...5 2 Test Setup Testing Notes ...
Page 56: ...5 1 18 Test Setup Testing for 380 430 MHz Notes ...
Page 116: ...A 10 Replacement Parts Kits Notes ...
Page 119: ......