Chapter 2. Initialization and Setup
2-11
System Power-up and Initial Operation
dBUG>
The board is now ready for operation under the control of the debugger as described in Chapter 3.
If you do not get the above response, perform the following checks:
1. Make sure that the power supply is properly configured for polarity, voltage level and
current capability (~300mA) and is connected to the board.
2. Check that the terminal and board are set for the same character format and baud.
3. Check that your switches are set to their default settings.
4. Press the RESET button to insure that the board has been initialized properly.
If you still are not receiving the proper response, your board may have been damaged. Contact
Axiom Manufacturing for further instructions, please see the beginning of this manual for contact
details.