MobileRFID Functionality
3 - 7
Configure RFID
RFID is in Server Mode by default. To configure RFID to operate in Client Mode:
1.
Invoke the MobileRFID menu, then tap
Configure RFID
.
Figure 3-10
RFID Configuration Window
2.
Select the
Client Mode
check box.
3.
In the
LLRP Port
field, enter the port number on which the server waits for the RFID client to communicate.
The default is 5084.
4.
In the
Server IP
field, enter the server IP for the remote host to which RFID communicates as a client.
5.
Tap
Apply
.
6.
Tap
OK
to close the window.