Adding a Temperature Analytic Event
The temperature events can be used to set up notifications or rules.
1. In the New Task menu
, click
Site Setup
.
2. Select a camera, then click
Analytic Events
.
3. Click
Add
.
4. Enter a name. This should be unique throughout the ACC site.
5. Select the
Enabled
checkbox. If the checkbox is clear, the video analytics event will not detect or
trigger any events.
6. Select the type of temperature event you want to add in
Activity:
and configure the event settings:
l
If
Object with elevated temperature
is selected, configure the
Elevated Temperature
Threshold (°C)
or
(°F)
: The threshold above which a person may need further screening.
Default is the calibrated value from the thermal camera. Any temperature detection above this
threshold will trigger the event.
l
If
Object with lower temperature
is selected, configure the
Lower Temperature Threshold
(°C)
or
(°F)
: The threshold below which a person may need further screening. Default is the
calibrated value from the thermal camera. Any temperature detection below this threshold will
trigger the event.
l
If
Object with expected temperature
is selected, configure both the lower and elevated
temperature thresholds. Any temperature detection that falls between the specified
thresholds is considered within the acceptable range and will trigger the event.
When a detected temperature matches the threshold defined, the event triggers the camera to
record for the specified duration.
7. People is automatically selected as the
Object Types:
and cannot be changed.
Ignore the Sensitivity:, Number of Objects:, and Threshold Time: settings.
8. In Timeout:, select the recording duration for the event from 2 to 15 seconds. The default setting is 8
seconds.
9. Click
OK
to save your settings.
Toggling Degrees Celsius and Fahrenheit
Toggle the temperature unit that displays next to the bounding box on faces in live video and in related
temperature detection activity events.
1. In the Windows Control Panel, select
Region
and
Additional settings
.
2. Select the unit in
Measurement system
.
3. Click
OK
. The temperature unit takes effect immediately.