Radio Types and Installation Kits
21-71
The initial screen is as follows:
MDS iNET 900
Starting Information Screen
-==================================================================-
Device Mode:
Access Point
Device Name:
AP Demo Set I
Network Name:
Demo Set l
IP Address:
169.254.0.12
Device Status:
Operational
Uptime:
01 hrs, 51 min
Firmware Version:
4.4.0
Hardware Version:
1.0.3
Serial Number:
1069975
Press 'G' to go to Main Menu
1.
Press 'G' and the Main Menu will be displayed.
2.
Press 'B' and the Network Configuration Menu will be displayed.
3.
Press 'G' for IP Address configuration.
4.
In the IP Address Configuration Menu, press 'B' to set the Static IP Address to
169.254.0.12.
5.
Next press 'C' to set the Static IP subnet mask to 255.255.0.0. It is recommended that all
units having the same AP (Access Point) be on the same subnet mask.
Note that the Static (sub)Net Mask and Static IP Gateway addresses should be the same
as those of the IP Gateway and EPIB. Their IP Address should be on the same subnet.
For example 169.254.0.100 for an IP Gateway address of 169.254.0.012 is suitable.
Also note that when using PPP it is recommended to have the IP Address of PPP on the
same subnet, for example 169.254.0.13. See Configuring for PPP below.
6.
Press 'E' to commit changes. Press ESC to return to the Network Configuration Menu.
7.
Finally press 'D' and enter the maximum number of remotes. By default this value is 50.
If the AP has more than that, you must change the value.
Summary of Contents for ACE3600 RTU
Page 45: ...Installation 2 25 ...
Page 46: ...Installation 2 26 Figure 2 28 19 Frame Metal Back Installation Combinations ...
Page 100: ...Digital Input Module 6 7 Module Block Diagram 16 DI ...
Page 101: ...Digital Input Module 6 8 32 DI ...
Page 120: ...Digital Output Digital Input FET Module 8 6 Module Block Diagram 16 DO DI FET ...
Page 121: ...Digital Output Digital Input FET Module 8 7 32 DO DI FET ...
Page 125: ...Digital Output Digital Input FET Module 8 11 Specifications subject to change without notice ...
Page 133: ...Digital Output Relay Module 9 8 Module Block Diagram 8 DO ...
Page 134: ...Digital Output Relay Module 9 9 16 DO ...
Page 155: ...Digital Output SBO Relay Module 11 9 Module Block Diagram 8 DO ...
Page 156: ...Digital Output SBO Relay Module 11 10 16 DO ...
Page 166: ...Analog Input Module 12 8 Module Block Diagram 8 AI ...
Page 167: ...Analog Input Module 12 9 16 AI ...
Page 178: ...Analog Output Module 13 8 Module Block Diagram 4 AO ...
Page 186: ...Mixed I O Module 14 5 Module Block Diagram Mixed I O ...
Page 193: ...Mixed Analog Module 15 4 Module Block Diagram Mixed Analog ...
Page 342: ...OPTIMIZATION General No optimization is required for the ACE3600 units 25 1 ...
Page 354: ...Break Fix Procedures Figure 29 3 Electrical Interconnection RTUs with I O slots 29 7 ...
Page 355: ...Break Fix Procedures 29 8 Figure 29 4 Electrical Interconnection RTUs with no I O slots ...