Installation
2-3
117 mm
209 mm
124 mm
82 mm
244 mm
124 mm
195 mm
161 mm
234 mm
199.6 mm
124 mm
244 mm
0 I/O Frame
2 I/O Frame
3 I/O Frame
Figure 2-2 No I/O, 2 I/O, and 3 I/O Frame Installation Dimensions and Screw Holes for
Installation
278.5 mm
314 mm
244 mm
124 mm
391 mm
356.9 mm
2
44 mm
1
24 mm
5 I/O Frame
7 I/O Large (or Redundant) Frame
Figure 2-3 5 I/O and 7 I/O Frame Installation Dimensions and Screw Holes for
Installation
Note: The default redundant CPU and power supply frame is the same size as the 7 I/O frame.
The following screw mount installation procedure should be used to install all ACE3600
frames (with or without a metal chassis) on a wall, except the 8 I/O (19") frame. For the 8 I/O
frame, see Installing the ACE3600 in a 19" Rack and Mounting the ACE3600 8 I/O Frame on a
Wall below.
Procedure 2-1 How to Mount the RTU Frame on a Wall
1)
Drill four holes in the wall at the horizontal and vertical distances shown in Figure 2-1,
Figure 2-2, and Figure 2-3.
2)
Insert M4 screws (not supplied) with head size DIN 7981C/ST4, 2x38mm into the holes.
3)
Remove the modules from the frame.
4)
Lift the RTU frame and hang over the four screws.
5)
Remove the outermost modules in order to access the screws.
Summary of Contents for ACE3600 RTU
Page 45: ...Installation 2 25 ...
Page 46: ...Installation 2 26 Figure 2 28 19 Frame Metal Back Installation Combinations ...
Page 100: ...Digital Input Module 6 7 Module Block Diagram 16 DI ...
Page 101: ...Digital Input Module 6 8 32 DI ...
Page 120: ...Digital Output Digital Input FET Module 8 6 Module Block Diagram 16 DO DI FET ...
Page 121: ...Digital Output Digital Input FET Module 8 7 32 DO DI FET ...
Page 125: ...Digital Output Digital Input FET Module 8 11 Specifications subject to change without notice ...
Page 133: ...Digital Output Relay Module 9 8 Module Block Diagram 8 DO ...
Page 134: ...Digital Output Relay Module 9 9 16 DO ...
Page 155: ...Digital Output SBO Relay Module 11 9 Module Block Diagram 8 DO ...
Page 156: ...Digital Output SBO Relay Module 11 10 16 DO ...
Page 166: ...Analog Input Module 12 8 Module Block Diagram 8 AI ...
Page 167: ...Analog Input Module 12 9 16 AI ...
Page 178: ...Analog Output Module 13 8 Module Block Diagram 4 AO ...
Page 186: ...Mixed I O Module 14 5 Module Block Diagram Mixed I O ...
Page 193: ...Mixed Analog Module 15 4 Module Block Diagram Mixed Analog ...
Page 342: ...OPTIMIZATION General No optimization is required for the ACE3600 units 25 1 ...
Page 354: ...Break Fix Procedures Figure 29 3 Electrical Interconnection RTUs with I O slots 29 7 ...
Page 355: ...Break Fix Procedures 29 8 Figure 29 4 Electrical Interconnection RTUs with no I O slots ...