8A
8B
EN
EN
04. CONNECTIONS
CONNECTION SCHEME
CONNECTION
COLOR
• Power supply
Red
• GND (0V)
Black
• Relay output (NC)
Green
• Relay output (COM)
Yellow
• Test input
Blue
Power Supply
GND (0V)
Relay output
(NC)
Relay output
(COM)
Test input
• Photocell
emitter (TX)
• Photocell
receiver (RX)
• Connecting
cable
• Sync Cable
OPERATING MODE
Photocells can operate in three different modes:
• SEQUENTIAL MODE
The photocell is able to differentiate between
an interruption caused by an object and the
movement of the door.
For this mode to work correctly, the door must be
opaque.
• SEQUENTIAL MODE FOR TRANSPARENT
TARPAULINS
The photocell is able to differentiate between
an interruption caused by an object and the
movement of the door.
For this mode to work properly, the bottom of
the tarpaulin must be opaque by at least 200mm.
• STATIC MODE
In this mode, the photocell will reverse
the maneuver when one of the sensors is
interrupted.
05. OPERATION
Min.
200mm