Reference
33
Manual # 42-02-U001, Rev C1
UPS Unit Information
Refer to the manual shipped with the UPS unit in addition to the following.
3kVA Units
UPS unit front panel indicators are similar from one size unit to the
next.
• Power switch: On/Off — CAUTION: Even when disconnected from
input power, high voltage may be present on UPS output connec-
tions when this switch is On (battery provided voltage).
• Test OK LED: For stand-alone UPS, lights green when self-test is
complete after Test/Silence button is pressed. NOT USED with
TAPS unit; use TAPS test instead. Refer to Test Button information
on page 4.
• Test/Silence button: Initiates test described above. Silences alarm
tone from UPS.
• Fault LED: Lights if the UPS detects an internal fault.
• Bypass LED: Lights when UPS is in bypass mode.
• Utility LED: Lights green when AC power is present and to indicate
100% battery/load level when supplying power.
• Inverter LED: Lights green when inverter is on and to indicate 75%
battery/load level when supplying power.
• Battery Low LED: Lights red when battery is low and to indicate
50% battery/load level when supplying power.
• Overload LED: Lights red to indicate an overload and to indicate
25% battery/load level when supplying power.
Table 11. TAPS VF Board Inputs
Inputs
Description
P1
Remote backup operation input - A test switch connected at the factory
to TAPS input P1 or on-site to a remote test button allows you to initiate
a run cycle to periodically determine that TAPS is functioning properly.
Please refer to “REMOTE BACKUP OPERATION:” on page 16
.
P2
Restart backup operation input - Optional input that can be used to
restart the TAPS unit after it has been shut down when the user defined
operating time parameter has expired.
BACKUP POWER OPERATION:” on page 16
P3
Rescue operation complete input - When high (+24V) this input forces
the KM5 relay to de-energize and prevent the TAPS unit from providing
backup power. This input is activated by the elevator control once the
TAPS recall/rescue cycle is complete
Please refer to “RESCUE OPERATION COMPLETE INPUT:” on page 17
.
Summary of Contents for TAPS
Page 6: ...2 Manual 42 02 D001 Rev A 1 September 2003...
Page 15: ...Installation 9 Manual 42 02 U001 Rev C1 Figure 5 6kVA UPS Enclosure Base Assembly...
Page 16: ...10 Manual 42 02 U001 Rev C1 Figure 6 6kVA UPS Enclosure Assembly...
Page 40: ...34 Manual 42 02 U001 Rev C1 6kVA Units The 6kVA unit uses an LCD as well as LEDs...
Page 42: ...36 Manual 42 02 U001 Rev C1 6 12 12...
Page 43: ...TAPS Drawings 37 Manual 42 02 U001 Rev C1...
Page 44: ...38 Manual 42 02 U001 Rev C1...