The room must be:
•
prepared so that conditions are appropriate for operation of the pellet stove
•
provided with an appropriate flue gas chimney system
•
provided with a 230V 50Hz (EN 73-23) power supply
•
Provided with permanent ventilation complying with national building regulation for solid
fuel appliances (or a direct air supply from outside to the pellet stove not less than 80 mm
diameter.
•
provided with a CE compliant earth connection.
The pellet stove must be connected to a SINGLE exhaust duct (chimney) or a vertical internal or
external duct in accordance with current provisions.
Combustion of timber (white) pellets causes smoke, which can deposit soot if it comes in contact
with walls.
Fitting a grille to the end of the chimney that may lead to poor operation of the stove is strictly
prohibited.
Approved flues and joints with appropriate silicone seals must always be used to ensure the
tightness of the flue.
No more than 3 no. 90° bends may be used to connect the chimney, and they may not be used
more than 2-3 m horizontally.
Stove location/ Clearance
Clearances only apply when the stove is to be placed near flammable materials. Your new st-
ove may be located as stated on the approval sign on the rear of the stove if the walls made of
flammable material.
Distance to furniture
The clearance to flammable material in front of the stove is 700 mm. With regard to positioning
furniture, the clearance to flammable material must be complied with, but you should consider
whether furniture and other items would be dried out so near the stove.
A pellet stove becomes hot when lit. You should therefore take the necessary care, especially
with regard to children coming into contact with the stove.
On the floor
If the stove is fitted on a combustible floor, the national and local provisions must be complied
with regard to the size of incombustible hearth required to cover the floor below the stove. You
should naturally ensure that the sheet can support the weight of the stove and possibly the
steel chimney. (The hearth temperature beneath the P30 and P31 pellet stove does not excede
100°)
The chimney
A modern efficient stove imposes greater requirements on your chimney. Therefore, you
should let the chimney sweep assess the chimney.
The chimney opening must comply with national and local provisions.
Too large a chimney opening leads to too much energy being used to heat the chimney to ob-
tain an acceptable draught. A brick chimney with a large opening must have an insulated lining
of the right diameter. This results in increased draught and better fuel economy.
There are no particular requirements for chimney height, but it must be high enough to obtain
a good draught and avoid smoke nuisance. As a general rule, a satisfactory draught is achieved
if the chimney is 4 metres above the stove and no less than 80 cm above the ridge. If the chim-
ney is on the side of the building, the top of the chimney should never be lower than the ridge
or the highest point on the roof. Morsø recommends a minimum draught in the chimney of 10
pa.
Chimney sweep
As mentioned, it may be wise to consult the local chimney sweep before installing the stove.
In any case, the chimney sweep must be informed when the pellet stove is fitted. If the chim-
ney has not been used for some time, it should be checked for cracks, birds’ nests etc. before
being used again.
Min. clearance to flammable material:
Installation Stove type
Distance
A
Distance B Distance C
Distance in front
of stove
Normal
right-angled
Morsø P30/31
uninsulated flues
200 mm.
200 mm.
-
700 mm
Corner
installation
Morsø P30/31
uninsulated flues
-
-
200 mm.
With regard to heat circulation, cleaning and possible internal cleaning of the stove, the re-
commended distance to walls is 10-15cm.
A
B
C
C
Revisions
Rev.
Sign.:
Title:
Drawing no.:
1:20
Afstand til brændbart
Morsø P30
RSV
24.10.12
A4
30.6
ERROR!:materiale
Date of print: 24-10-2012
U:\udv\Tegninger\Pilleovn\Morsø P30\Morsø P30 kofiguration 01A\070-MO-001A.sldasm
P30-06 a
Itemno.:
This drawing is Morsø Jernstøberi A/S' property and must not be sold, lended or copied without any written authorization from the company.
Material:
Weight kg.:
Model no.
Drawingtype:
Location of file:
Scale:
Format:
Released:
Construction:
Date: