22
23
Sprog
Sprog
2.7 Functions and operation of your stove
THE MODULE PHASE
During the operating phase (Operation), the aim of the pellet stove is to reach the set room
temperature. As soon as this temperature is reached, the pellet stove goes into the MODULE
phase. This is the phase during which fuel consumption is least, and the convection fan runs at
lower speed. MODULE and power step 1 are identical.
Altering power step
Press key 1 to change the power and set the desired power from 1 to 5 using keys 1 and 2.
Increasing power increases pellet consumption and convection fan speed. The power setting
cannot be changed during the MODULE phase. The stove will only change to the other power
step when the stove is in normal operation.
Climate Comfort
With this programme, the stove maintains the temperature in a chosen area.
To access CLIMATE COMFORT, press keys 4 and 6 together. When the required room tempe-
rature has been reached, the stove enters MODULE and then ECO STOP, in which the stove
is turned off entirely. The degrees chosen on this menu is not the room temperature, but the
number of degrees the room temperature must fall below the chosen room temperature be-
fore restarting.
PR 42
OFF
COMFORT
CLIMATE
To activate Climate Comfort press key 5 and set the va-
lue from 1 to 20 (°C). It is recommended that the Climate
Comfort value be set to a minimum of 3°C and that the
stove should run for 45 minutes or more between star-
ting and stopping. This is to protect the ignition tube in
the stove, which will otherwise wear out too quickly. OFF
means that CLIMATE COMFORT is deactivated.
PR 42
3°
COMFORT
CLIMATE
The value has in this case been set to 3°.
KLIMA KOMFORT is now activated and functions in the
following manner: The value determines when the stove
starts again.
Example: Set room temp. 21°C Climate Comfort value
3°C. The stove will be turned off at approx. 21°C and
turned on again when the temperature is approx. 17°C
(21°C-3°C-0.5°C = 17°C)
P - 2
10:30 21°
MODUL
The stove goes into the MODULE phase when the room
temperature is reached. If the temperature stays at 21°C
for some minutes, will the stove will initiate the shut-
down phase.
P - 2
10:34 21°
ECO
STOP
Once the stove has shut down, the display will show ECO
STOP. It will remain in this condition until the tempera-
ture decreases to approx. 17°C, when the stove will be
re-started.
NOTE: The stove can turn off and on many times during the day. This will mean more wear
on the ignition tube. The ignition tube is not covered by the guarantee!
Changing the room temperature setting
The pellet stove can use two types of room thermostat:
•
The room temperature sensor supplied, fitted to the rear of the pellet stove.
•
External room thermostat (not supplied).
Operation with room temperature sensor supplied
If room temperature sensor supplied is used, the room temperature will be shown on the dis-
play. To set the required temperature, press key 4 to access the relevant menu and set the
value with keys 4 and 5 from 7°C to NAn (NAn means that sensor is out of action). As soon as
the set temperature is reached, the text MODULE is shown on the display and the pellet stove
reduces pellet consumption to a minimum by lowering the heating power, corresponding to
power step 1.
Operation with external room thermostat
If an external room thermostat is used, correctly connected to the printed circuit board (see
wiring diagram on page 37), the room temperature will not be shown on the display. Instead, it
will show T ON when the switch is closed and T OFF when the switch is open.
NOTE: To activate the external thermostat, press key 4 repeatedly until the display shows
EST, and confirm with key 6.
The room temperature is directly regulated by the thermostat fixed on the wall. As soon as the
set temperature is reached, the text MODULE is shown on the display, and the pellet stove re-
duces pellet consumption to minimum by lowering the heating power. If CLIMATE COMFORT is
activated, the stove will be turned off.
Adjusting combustion
Combustion can be adjusted in a simple manner by changing the quantity of air and pellets.
Combustion can be increased or lowered by changing the draught in the chimney and adjusting
according to the quality/hardness of the pellets.
IMPORTANT!
THE SET ROOM TEMPERATURE ON THE STOVE MUST BE EST (...8, 8, 7, EST)
WE RECOMMEND AN EXTERNAL ROOM THERMOSTAT WITH A MINIMUM SENSITIVITY OF
3°C FOR CLIMATE COMFORT TO FUNCTION CORRECTLY.
0
PELLETS
0
DRAUGHT
To access regulation, press keys 6 and 7 together.
Factory Setting is 0.