11
TriStar MPPT 600V Operator’s Manual
10
Important Safety Instructions
Getting Started
2.0
2.1 Overview
Thank you for selecting the TriStar MPPT 600V charge controller with TrakStar
TM
MPPT
Technology. The TriStar MPPT 600V (TS-MPPT-60-600V) is an advanced maximum power point
tracking solar battery charger. The controller features a smart tracking algorithm that finds and
maintains operation at the power source's peak power point, maximizing energy harvest.
The TriStar MPPT 600V battery charging process has been optimized for long battery life and
improved system performance. Self-diagnostics and electronic error protections prevent damage
when installation mistakes or system faults occur. The controller also features eight (8) adjustable
settings switches, several communication ports, and terminals for remote battery temperature
and voltage measurement.
Please take the time to read this operator’s manual and become familiar with the controller. This
will help you make full use of the many advantages the TriStar MPPT 600V can provide for your
PV system.
2.2 Regulatory Information
NOTE: This section contains important information for safety
and regulatory requirements.
The TriStar MPPT 600V controller should be installed by a qualified technician according to the
electrical rules of the country in which the product will be installed.
TriStar MPPT 600V controllers comply with the following EMC standards:
• Immunity: EN61000-6-1
• Emissions: EN61000-6-3+A1, ICES-003 Issue 5 (Class B)
• Safety: EN62109-1, EN60335-1 and EN60335-2-29 (battery chargers)
A means shall be provided to ensure all pole disconnection from the power supply. This
disconnection shall be incorporated in the fixed wiring.
Using the TriStar MPPT 600V grounding terminal (in the wiring compartment), a permanent and
reliable means for grounding shall be provided. The clamping of the earthing shall be secured
against accidental loosening.
The entry openings to the TriStar MPPT 600V wiring compartment shall be protected with conduit
or with a bushing.
FCC requirements:
This device complies with Part 15 of the FCC rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must accept
any interference received, including interference that may cause undesired operation. Changes
or modifications not expressly approved by Morningstar for compliance could void the user’s
authority to operate the equipment.
• Des gaz explosifs de batterie peuvent être présents pendant la charge. Assurez-vous qu’une venti-
lation suffisante évacue les gaz.
• Ne fumez jamais dans la zone des batteries
• En cas de contact de l’électrolyte avec la peau, lavez avec du savon et de l’eau. En cas de contact
de l’électrolyte avec les yeux, rincez abondamment avec de l’eau fraîche et consultez un médecin.
• Assurez-vous que le niveau d’électrolyte de la batterie est correct avant de commencer la charge.
Ne tentez pas de charger une batterie gelée.
• Recyclez la batterie quand elle est remplacée.
About this Manual
This manual provides detailed installation and usage instructions for the TriStar MPPT 600V
controller. Only qualified electricians and technicians who are familiar with solar system design
and wiring practices should install the TriStar MPPT 600V. The usage information in this manual
is intended for the system owner/operator.