23
MORNINGSTAR
CORPORATION
The channel is now configured for Alarm/Fault mode. The
Relay Driver Setup screen should display the Alarm/Fault
Function parameters in the Configuration Summary for the
channel.
If all four channels are now configured as desired, refer to
section 3.3 for instructions on how to program the Relay
Driver.
Alarm/Fault
Advanced
Setup Definitions
The following definitions can be used when configuring the
Alarm/Fault Function in
Advanced
setup. These values are
assigned the appropriate default values in
Simple
setup.
Control Address
– The meter bus ID for the device that is to
be monitored. Factory default is one (1) for the TriStar and
nine (9) for the Relay Driver. (Not applicable in Standalone)
Sample Period
- How often the Relay Driver polls the
Morningstar Device.
Timeout
– Period of time to wait for a response from the
Morningstar Device before setting a communications Timeout
fault.
Timeout State
- Determines the behavior of the channel if a
communications timeout occurs.