Important Safety Instructions
4
Ground Symbol
• This charge controller is to be connected to DC circuits
only. These DC connections are identified by the symbol
below:
Direct Current Symbol
The ProStar MPPT controller must be installed by a qualified
technician in accordance with the electrical regulations of
the country of installation.
A means of disconnecting all power supply poles must be
provided. These disconnects must be incorporated in the
fixed wiring.
The ProStar MPPT negative power terminals are common,
and must be grounded as instructions, local codes, and
regulations require.
A permanent
,
reliable earth ground must be established
with connection to the ProStar MPPT ground terminal.
The grounding conductor must be secured against any
accidental detachment.
Précautions de Sécurité D’installation
AVERTISSEMENT:
L’appareil n’est pas fourni avec un
dispositif GFDI. Ce contrôleur de charge doit être
utilisé avec un dispositif GFDI externe tel que requis
par l’Article 690 du Code électrique national de
l’emplacement de l’installation.