airflow and that the heatsink temperature is approaching
unsafe limits. If the controller frequently reports this alarm
condition, corrective action must be taken to provide better
air flow or to relocate the controller to a cooler spot.
High Input Voltage Current Limit
The ProStar MPPT will limit the solar input current as the
solar array Voc approaches the maximum input voltge
rating. The array Voc should never exceed the 120 volt
maximum input voltage - see the array voltage de-rating
graph in Appendix.
Current Limit
The array power exceeds the rating of the controller. This
alarm indicates that the ProStar MPPT is limiting battery
current to the maximum current rating.
RTS Open
The Remote Temperature Sensor is not connected to the
controller. Use of the RTS is recommended for proper
battery charging.
Heatsink Temperature Sensor Open / Shorted
The heatsink temperature sensor is damaged. Return the
controller to an authorized Morningstar dealer for service.
Battery Sense Out of Range / Disconnected
A battery sense wire is disconnected. Inspect the battery
sense connections. This alarm is set when the voltage at the
battery sense voltage differs by more than 5 volts from the
voltage at the battery terminals.
Uncalibrated
The controller was not factory calibrated. Return the
controller to an authorized Morningstar dealer for service.