ELECTRA
C
OMFORT
25
This parameter could be set only by
Value 0-half the max. power output, a step by the set
†
authorized service technique!
value of parameter P35.
Operation of the boiler in HT is possible
only on the basis of permission of
This parameter could be set only by
official electricity network distributor!
authorized service technique!
P23-Selection of maximal output for heating of
TUV (sanitary water) with high price tariff (HT), (0
P27-Selection of lightening relay function in 2nd
- 22,5 kW).
level (0- 12, 5 kW)
Using this parameter you are able to limit output of
†
the boiler for heating into the storage water tank TUV
Using this parameter you are able to set how the
†
(sanitary water) with high price tariff (HT).
nominal output will be lighted in case of the signal of
Value 0 to 22.5 maximum power output in kW, the
†
2nd level from the lightening relay placed in consumer
step according to the mounted heating rod type (see
board unit.
Parameter Tab., P35).
Value 0-half the max. power output, a step by the
†
set value of parameter P35.
This parameter could be set only by
authorized service technique!
This parameter could be set only by
authorized service technique!
Operation of the boiler in HT is possible
only on the basis of permission of
official electricity network distributor!
P28- Selection of manual switching on of HDO
(mass remote control) signal
P24-Selection of maximal output for heating of
whole system with low price tariff (NT), (0- 22, 5
Using this parameter it is possible to simulate the HDO
kW)
†
signal (activation of low price tariff NT). This parameter
is automatically deactivated after 10 min. This
Using this parameter you are able to limit output of the
†
parameter is only for service and after sales service
boiler for heating system during its operation with low
purposes including boiler setting.
price tariff (NT) HDO (mass remote control) signal.
HDO (mass remote control) it is not active.
†
Value 0 to 22.5 maximum power output in kW, the
†
O.K. HDO is activated after its confirmation for 10 min.
†
step according to the mounted heating rod type (see
Parameter Tab., P35).
This parameter could be set only by
authorized service technique!
This parameter could be set only by
authorized service technique!
P29- Selection of safety PIN code
P25-Selection of maximal output for heating of
Using this parameter it has to be set PIN SIM card
†
TUV (sanitary water) with low price tariff (NT),
inserted in GSM mode. In case that SIM card is not
(0 - 22, 5 kW)
by PIN protected, this number could each one.
The value xxxx four places number.
†
Using this parameter you are able to limit output of the
†
boiler for heating into the storage water tank TUV
For this possibility of remote GSM control
(sanitary water) with low price tariff (NT) HDO (mass
of the boiler it is necessary to buy a GSM
remote control) signal.
model!
If you insert the wrong number of PIN
Value 0 to 22.5 maximum power output in kW, the
†
then you could block the SIM card!
step according to the mounted heating rod type (see
Parameter Tab., P35).
P30-Selection of the user No. 1 responsible for
remote GSM communication with the boiler
This parameter could be set only by
authorized service technique!
Using this parameter it has to be inserted GSM mobile
†
phone number of the user responsible for remote GSM
communication with the boiler through SMS. The
P26-Selection of lightening relay function in 1st
number has to be inserted in the international number
level (0 - 12, 5 kW)
format and if the number is shorter than 13 places then
it is necessary to insert for free ending place “N”.
Using this parameter you are able to set how the
†
The value 0, 1, 2, …9, N + - marking of phone number
†
nominal output will be lighted in case of the signal of 1st
level from the lightening relay placed in consumer
board unit.