Without the room thermostat connected
With the room sensor connected (on the display there is
marked by the symbol .
In case that the room sensor is connected (the order
number of set is 4050485) the boiler is heating according
to the temperature in a reference room with hysteresis 1
°C. Actual temperature in the reference room is displayed
under the symbol .The room sensor is connected on the
clamps of the control unit marked NTC ROOM.
Steps for setting of temperature in a reference room
Press the button , on the control panel, for setting of the
temperature requested press for its increasing or
for its decreasing and confirm it by . After this
confirmation you will go back to main display.
Temperature could be set in scale from 5 to 35 °C, if the
temperature is decreased below 5°C the regulation
function is switched off on the basis of reference room
temperature. The boiler is controlled by the same way as
in previous 2 samples without the importance of the
temperature in reference room. The temperature will not
Regulation is depended on the temperature of boiler water
be shown on the display.
requested by the user and hysteresis set by the parameter
Remarks:
if you have reference room temperature
P20 in the scale 1 - 10 °C. (This parameter could be set
regulation activated then this regulation is priority (and
only by authorized service person).
the boiler will not reply to room thermostat).
Steps for temperature setting of heating water:
Set the temperature requested by pushing , on the
control panel , on the display is temperature and “OV
TEPLOTA” and confirm by .After confirmation you will
go back to the basic display. The boiler is now heating to
the temperature requested by you. The scale of
temperature setting is 25 80 °C (regarding the setting
below the temperature value 25 °C the marking of
operation mode “SUMMER” = “SU” is lighting, going back
to heating mode is possible only by increasing the
temperature of heating water by the button ) .
If you don't confirm the value during editing till. 10 s, the
boiler is automatically goes back to the previous setting.
We recommend you to use the room thermostat for
economical operation of your heating system
With the room thermostat
Steps for setting of temperature in a reference room with
GSM modem(Only if you have GSM modem order No.
9566.2010 connected to the boiler)
The temperature in a reference room it is possible to set
also like a remote control through SMS in a format
example *22 (star, temperature in °C without spaces)
according to the way described in a instruction manual of
GSM modem.
With equitermic regulation
equitermic regulation is not depended on instruction
†
from control elements of the boiler, it is determined
only for setting the temperature of heating water on
the basis of outdoor temperature.
In case that the room thermostat is connected the
this mode it is possible to be activated by connection of
†
regulation of temperature is the same as in case
outdoor sensor (set of outside sensor order No.
without the room thermostat connected till the moment
4841815 of control unit “NTC OUT”) and setting of
when the request for heating is stopped by the room
equitermic curve regulation is done by the parameter
thermostat.
GSM module works only in the nets with
standartized GSM protocol.
+
-
+
+
-
4
5
5
6
1 -
4 -
5 -
6 -
boiler
heating system
closing valve
filter
1
1 -
4 -
5 -
6 -
10 -
boiler
heating system
closing valve
filter
temperature sensor
in reference room
4
5
5
6
10
1
9
4
5
5
6
1 -
4 -
5 -
6 -
9 -room thermostat
boiler
heating system
closing valve
filter
1