temperature of heating water using the button - below
2.3 Modes
25° C and confirmed this by .In this operation mode
the boiler is heating only the storage water tank (3-
Important information for setting
ways valve is permanently in position in position
during editing “help” is lighting in the low line for the
“tank”). It is possible to go from this operation mode to
†
value to be set
operation mode “Winter” by increasing of heating water
temperature using and confirm it by .
during the first pushing of each button the editing is not
†
active
Operation mode “stand by”
in delay in setting more than 10 s the editing is without
†
on the display there is
†
the change, it means that the setting is going back to
this operation mode is activated by long pushing (3 s)
the starting position (only if the editing was not
†
confirmed )
the button and deactivated by short pushing .
each value set has to be confirmed by button .
Concerning this operation mode there are only active
†
†
protective functions described in the chapter 1.7.4
if the value setting is not wanted or wrong (for example
†
entering the parameters setting), wait 10 s and the
2.3.1 Mode heating (heating water)
boiler is automatically going back to starting basic
display or it is also possible to “enter” the parameter by
pushing the button , .
on the display there is the symbol
†
By holding the button , the setting value will
†
this manual mode is active in operation mode
†
automatically rolls up or down
“WINTER” “WI”“
In case of wrong parameters setting it is possible to go
†
back to “factory setting” according to these steps:
switch off the boiler using the main switcher, push
together and switch on the boiler. On the
display there is “reset of factory parameters” and after
OK is displayed then the parameters are according to
factory setting.
Main operation modes
Operation mode “winter”
on the display there is “WI”
†
this operation mode is active always when the
†
temperature of heating water is set (it means the
operation mode “SU” is not lighting). In this operation
mode the boiler is heating the system and also the
storage water tank (if it is connected through)
Operation mode “summer”
on the display there is “SU”
†
this mode is possible to activated by reducing the
†
+
-
+
-
+
ELECTRA
C
OMFORT
18
2.2 The boiler switching ON/OFF
Use the switcher 0/1 placed on the right corner of bottom side of the boiler (see the picture 1.6 Main parts)
On the display there is displayed introductory information after boiler's switching on.
E - KOMFORT: 22,5 kW
TUV: NE VER.1.20
- electric boiler ELECTRA comfort with output 22,5 kW
- TUV mode is not connected, SW version 1.20
Switchboard of the boiler and inlet conductors and clamps of the contactor and inlet conductor
of the switcher are under voltage!
Disconnect the boiler from the main electric inlet supply!
Example::