6 The Interface Solution Experts
Programmable Isolated
Thermocouple Transmitter
TIY
Table 1.
Range Limits and Accuracy for the TIY with Thermocouple Input
Input
Type
J
K
E
T
R
S
N
B
No
Code
Range
Code
J1
J2
J3*
K1
K2
E1
E2
E3
T1
T2
T3*
R1
S1
N1
N2
B1**
PRG
Lower
1
(= to 4mA)
-50°C (-58°F)
-50°C (-58°F)
-130°C (-202°F)
-50°C (-58°F)
-50°C (-58°F)
-10°C (14°F)
-100°C (-148°F)
-100°C (-148°F)
-50°C (-58°F)
-100°C (-148°F)
-190°C (-310°F)
-18°C (0°F)
-18°C (0°F)
-50°C (-58°F)
-50°C (-58°F)
200°C (392°F)
Maximum
Zero
375°C (707°F)
560°C (1040°F)
80°C (176°F)
350°C (662°F)
1120°C (2048°F)
275°C (572°F)
800°C (1472°F)
0°C (32°F)
300°C (572°F)
40°C (104°F)
-40°C (-40°F)
1310°C (2390°F)
1310°C (2390°F)
950°C (1742°F)
550°C (1022°F)
1220°C (2228°F)
Upper
2
(= to 20mA)
450°C (842°F)
760°C (1400°F)
130°C (266°F)
450°C (842°F)
1370°C (2498°F)
350°C (662°F)
1000°C (1832°F)
50°C (122°F)
400°C (752°F)
100°C (212°F)
50°C (122°F)
1760°C (3200°F)
1760°C (3200°F)
1300°C (2372°F)
700°C (1292°F)
1820°C (3308°F)
Input
±0.08°C (±0.14°F)
±0.25°C (±0.45°F)
±0.06°C (±0.10°F)
±0.10°C (±0.18°F)
±0.30°C (±0.54°F)
±0.10°C (±0.18°F)
±0.25°C (±0.45°F)
±0.06°C (±0.10°F)
±0.10°C (±0.18°F)
±0.08°C (±0.14°F)
±0.12°C (±0.21°F)
±0.60°C (±1.08°F)
±0.50°C (±0.90°F)
±0.40°C (±0.72°F)
±0.15°C (±0.27°F)
±0.08°C (±0.14°F)
Output
3
±0.05% of span
±0.05% of span
±0.05% of span
±0.05% of span
±0.05% of span
±0.05% of span
±0.05% of span
±0.05% of span
±0.05% of span
±0.05% of span
±0.05% of span
±0.05% of span
±0.05% of span
±0.05% of span
±0.05% of span
±0.05% of span
Reference
Junction
Compensation
±0.25°C (±0.45°F)
±0.25°C (±0.45°F)
±0.25°C (±0.45°F)
±0.25°C (±0.45°F)
±0.25°C (±0.45°F)
±0.25°C (±0.45°F)
±0.25°C (±0.45°F)
±0.25°C (±0.45°F)
±0.25°C (±0.45°F)
±0.25°C (±0.45°F)
±0.25°C (±0.45°F)
±0.25°C (±0.45°F)
±0.25°C (±0.45°F)
±0.25°C (±0.45°F)
±0.25°C (±0.45°F)
±0.25°C (±0.45°F)
Specify when input type and range are undetermined or when unit will be stocked as a universal spare
(PRG default is J1-0-200°C)
*SP1 option required for J3 and T3 Range Codes (replace N1 and N2 Range Codes)
**SP2 option required for B1 Range Code (replaces S1 Range Code)
Notes:
1. The TIY output will limit at values which are 5% of maximum span lower than this value and will then display "–LO–".
2. The TIY output will not display values which are 10% of maximum span greater than this value. When exceeded, the display
reads "–HI–".
3. Output accuracy is in relation to the unit's calibrated span. See Table 1 and Table 2 for additional span accuracy information.
4. Valid for 400°C and above.