ELECTRONICS INFORMATION
Valve connectors
Possible connectors
Please note information regarding input signals on the nameplate!
Valve electronics with supply voltage
±
15 VDC and
6+PE pole connector
ATTENTION
Number
Supply Voltage
of Pins
±
15 VDC
24 VDC
6 + PE
X
X
11 + PE
–
X
11 + 1 (PE) Bayonet
X
–
6 (old, without PE)
X
–
12 (old, without PE) Bayonet
X
–
General Requirements
➢
Supply
±
15VDC
±
3%. Ripple < 50 mV
PP
. Current consumption max.
±
250mA
➢
All signal lines, also those of external transducers, shielded
➢
Shielding connected radially to (0V), power supply side and connected to
the mating connector housing (EMC)
➢
EMC
: Meets the requirements of EN 55011/03.91 class B,
EN 50081-1/01.92, and EN 50082-2/03.95, performance criterion class A
➢
Protective grounding lead
≥
0.75mm
2
(AWG 16)
➢
Note: When making electric connections to the valve (shield, protective
grounding), appropriate measures must be taken to ensure that locally
different earth potentials do not result in excessive ground currents.
See also MOOG Application Note AM 353 E.
a.
Command input
Command signal 0 to
±
10 V
The spool stroke of the valve is proportional to (U
D
– U
E
). 100% valve
opening P
➔
A and B
➔
T is achieved at (U
D
–U
E
) = +10 V.
At 0 V command
the spool is in the center position.
The input stage is a differential amplifier.
If only one command signal is
available, pin D or E is connected to signal ground (pin C) according to
the required operating direction (to be done at the mating connector).
Command signal 0 to
±
10 mA
The spool stroke of the valve is propor tional to (I
D
– I
E
).
100% valve opening P
➔
A and B
➔
T is achieved at (I
D
– I
E
)
= +10 mA.
At 0 mA command the spool is in the center position.
Either pin D or E is used according to the required operating direction. The
unused pin is left open (not connected at the mating connector). The input
pins D and E are inverting.
b.
Monitoring output
Actual value 0 to
±
10 V
The actual spool position value can be measured at pin F. This signal
can be used for monitoring and fault detection purposes.
The spool stroke range corresponds to
±
10 V. +10 V corresponds to
100% valve opening P
➔
A and B
➔
T.
Actual value 0 to
±
10 mA
The actual spool position value can be measured at pin F. This signal
can be used for monitoring and fault detection purposes.
The spool stroke range corresponds to
±
10 mA. +10 mA corresponds
to 100% valve opening P
➔
A and B
➔
T.
+ 15 VDC
±
3%, ripple <50 mV
pp
- 15 VDC
±
3%, ripple <50 mV
pp
0 to
±
10 mA
Load resistance 400
Ω
Current command
0 to
±
10 mA
Load resistance 400
Ω
Voltage command
0 to
±
10 V
Input resistance 100 k
Ω
0 to
±
10 V
Input resistance 100 k
Ω
Supply
Supply
Supply/signal ground
Input command
valve flow
Input inverted command
valve flow
Output actual value
spool position
For valve with 6+PE-pole connector according DIN 43563, connector (metal) with leading ground pin (
).
Function
Cabinet
side
Connector
Mating
connector
Valve
side
Protective ground
Connector Wiring
- Type code
S
(see sticker on the electronics housing)
( 0 V )
0 to
±
10 mA
Load resistance max. 500
Ω
0 to
±
10 V
Output resistance 10 k
Ω
1
) Valves having code letter
X
at position 10 of type
designation: Command signal 10 mA between pins D
and E (differentially, internal resistance 1 k
Ω
).
6