background image

8. TOOLS AND EQUIPMENT

a.

5mm Allen  wrench

b.

3mm Allen  wrench

c.

Large blade screwdriver

d.

Small screwdriver

e.

Scriber or small screwdriver

f.

Clean grease (mounting and insertion of O-rings)

The D661 Series valves require tools for installation, set up, null

adjustment and filter replacement.

➢ 

Installation of the valve

➢ 

Mounting of the D661 Series requires 5mm Allen wrench

➢ 

Null adjust of the valve at set up

➢ 

Large blade screwdriver to remove the cover screw

(see cut-away diagram on page 1)

➢ 

Small screwdriver for zero setting on internal potentiometer

Replacement Parts

Part Description

D661-

Qty.

Part Number

O-Ring, ports P,  T,  A, B, (T

2

)

all

5

42082-004

O-Ring, ports X&Y

all

2

42082-011

Replaceable Filter Disk

P...A/B

1

A67999 200

Replaceable Filter Disk

G, S, H & P...F/G

1

A67999 100

O-Ring, behind filter disk

all

1

A25163 013 015

O-Ring, for filter cover

P...A/B

1

B97009 080

O-Ring, for filter cover

G, S, H

1

A25163 017 020

Allen Setscrew, ports X & Y

G & P

2

66166 040 006

Screw plug, port X

S & H

1

66098 040 006

Seal, port X

S & H

1

A25528 040

Accessories 

(not part of the valve delivery)

Part Description

D661-

Qty.

Part Number

Mating Connector,
waterproof, protection IP65

   6+PE-pole

DIN 43563

B97007 061

   11+PE-pole

DIN 43651

B97024 111

   11+1-pole (Bayonet)

MIL C-26482/14-12

B97027 012

   6-pole

MIL C-5015/14S-6

A26201 004

   12-pole (Bayonet)

MIL C-26482/14-12

B97027 012

Mounting Manifolds

See special data sheet

Mounting Bolts
   M6x60 DIN 912-10.9

...G and ...P

4

A03665-060-060

   M6x55 DIN 912-10.9

...H and ...S

4

A03665-060-055

Flushing Plate

B67728-001

Flushing Plate

B67728-002

Flushing Plate

B67728-003

12

7. ELECTRICAL NULL ADJUSTMENT

The hydraulic null of the valve is preset at the factory with a tolerance

of 

±

 2% of rated signal.  If necessary, this null can be readjusted by the user of

the valve.

a.

Observe operating instructions for the machine/plant.
Valves with +4 to +20 mA command signal: Do not adjust valve

null! Contact machine/plant manufacturer.

b.

Procedure: Remove the command signal to the valve only by

disconnecting command signal lead at the cabinet.

Do not remove valve mating connector!

Remove cover screw on electronics housing to access the null adjust

potentiometer. Use a small screwdriver (blade width 2.5 mm) to turn

the potentiometer screw either clockwise or counterclockwise. Usually

it will not be necessary to turn the screw more than 2 turns in either

direction (

±

 1 turn is equivalent to 

±

 15% null shift).

c.

While adjusting, watch the actuator (motor) motion to find the null

position. With overlapped valves, turn the null adjust screw carefully in

both directions to just start motion and then back into deadzone

midposition between those two screw positions.

d.

After proper null adjustment, reconnect the command signal lead and

install protective cover screw again.

DANGER

ATTENTION

Summary of Contents for D661 series

Page 1: ...irements D661 G S and H The spool of the main stage is driven by a nozzle flapper or ServoJet pilot stage optional with or without additional mechanical feedback nozzle flapper only With versions D661...

Page 2: ...Stage Valve An electric input signal flow rate command is applied to the integrated control amplifier which drives a current through the coil of the pilot stage torque motor The thus deflected jet pip...

Page 3: ...ries catalog Series D661 for code letter of valve version see pages 18 19 G S F S G H P A P B Mounting pattern ISO 4401 version G with second tank port ISO4401 05 05 0 94 ISO4401 05 05 0 94 With serie...

Page 4: ...necessary stop the machine immediately and secure it c In the event of malfunctions stop the machine plant immediately and secure it Have any defects rectified immediately d If the machine plant is c...

Page 5: ...place flushing elements in the pressure filters by suitable high pressure elements after flushing Install Moog proportional valve instead of flushing plate or directional valve Setting Up a Set up mac...

Page 6: ...ol stroke of the valve is proportional to ID IE 100 valve opening P A and B T is achieved at ID IE 10 mA At 0 mA command the spool is in the center position Either pin D or E is used according to the...

Page 7: ...stroke range corresponds to 10V 10V corresponds to 100 valve opening P A and B T Command signal 0 to 10 mA The spool stroke range corresponds to 10 mA 10 mA corresponds to 100 valve opening P A and B...

Page 8: ...oke of the valve is proportional to ID IE 100 valve opening P A and B T is achieved at ID IE 10 mA At 0 mA command the spool is in the center position Either pin D or E is used according to the requir...

Page 9: ...V corresponds to 100 valve opening P A and B T Command signal 0 to 10 mA The spool stroke range corresponds to 10 mA 10 mA corresponds to 100 valve opening P A and B T Command signal 4 to 20 mA The sp...

Page 10: ...in the center position Either pin D or E is used according to the required operating direction The unused pin is left open not connected at the mating connector The input pins D and E are inverting C...

Page 11: ...value will be used with a machine control system the differential input circuit must be used Another option is to use the aforementioned circuit for the 6 PE pole connector Pin 6 according to DIN 43...

Page 12: ...S 6 A26201 004 12 pole Bayonet MIL C 26482 14 12 B97027 012 Mounting Manifolds See special data sheet Mounting Bolts M6x60 DIN 912 10 9 G and P 4 A03665 060 060 M6x55 DIN 912 10 9 H and S 4 A03665 060...

Page 13: ...signal at Pin D 2 Send to Moog factory for repair 1 With 15 VDC supply check for supply voltage at pins A and B being stable within 3 of 15V 2 With both 15VDC and 24 VDC supply at zero command and nor...

Page 14: ...10 bar X and Y external operating pressure in ports P A B and T up to 350 bar possible K 350 bar with dropping orifice in filter cover Valve connector S 6 PE pole EN 175201 Part 804 E 11 PE pole EN 17...

Page 15: ...haracter Y 4 way critical lap curvilinear characteristic X Special spool on request Options may increase price Technical changes are reserved Valve connector for supply voltage S 6 PE pole DIN 43563 0...

Page 16: ...0018 Telephone 716 652 2000 Fax 716 687 7910 Toll Free 1 800 272 MOOG http www moog com CDS6845 Rev A 500 406 0405 The products described herein are subject to change at any time without notice inclu...

Reviews: