Wire Gauge

Total vA 

consumed

,5

22

,75

20

1,0

18

1,5

16

2,5

14

4

12

6

10

MM

2

AWG

5.5

ft

 

m

400

   

121

600

   

182

960

   

292

-

-

-

10

120

   

36.5

180

   

54.9

300

   

91.4

480

   

146

800

   

243

1300

   

396

-

20

86

   

27.1

141

   

43.0

225

   

68.6

358

   

109

571

   

174

905

   

275

1440

   

438

30

65

   

19.8

90

   

27.4

130

   

39.6

225

   

68.6

350

   

106

525

   

160

830

   

252

40

44

   

13.4

70

   

21.3

112

   

34.1

179

   

54.6

285

   

86.9

452

   

138

720

   

219

50

35

   

10.6

56

   

17.1

90

   

27.4

143

   

43.6

228

   

69.5

362

   

110

576

   

175

60

29

   

9.4

47

   

14.3

75

   

22.9

119

   

36.2

190

   

57.9

301

   

91.7

480

   

146

70

25

   

8.8

40

   

12.2

64

   

19.5

102

   

31.1

163

   

49.7

258

   

78.6

411

   

125

80

31

   

7.6

34

   

10.3

55

   

16.8

85

   

25.9

140

   

42.7

215

   

65.5

340

   

103

These are recommended maximum distances

for 24VAC with a 10% voltage drop. 

•  Éstos se recomiendan las distancias máximas para 

24VAC con una caída de voltaje del 10%.

•  Ceux-ci sont recommandés des distances maximum 

pour 24VAC avec une chute de tension de 10%.

•  Diese werden maximale Abstände für 24VAC mit 

einem 10% Spannungsabfall empfohlen.

•  Estes são recomendados distâncias máximas para 

24VAC com uma queda de tensão de 10%.

•  Questi sono suggeriti distanze massime per 24VAC con 

una differenza de potenziale di 10%.

Wiring for Pressurized Receiver model (PDDW10CR2).

•   Cableado para el modelo a presión del receptor 

(PDDW10CR2).

•  Câblage pour le modèle pressurisé de récepteur 

(PDDW10CR2).

•  Verdrahtung für unter Druck gesetztes 

Empfängermodell (PDDW10CR2).

•  Fiação para o modelo pressurizado do receptor 

(PDDW10CR2).

•  Collegamenti per il modello pressurizzato della 

ricevente (PDDW10CR2).

A

B

C

D

E

F

G

H

R

J

K

L

M

N

P

U

T

S

NC

Alarm Common

Alarm In 3

Alarm In 2

Alarm In 1

RXB

TXB

TXA

Heater /Blower

Heater /Blower

Camera Power

Camera Power

Shield

Video 

NC

RXA

NC

Wiring for Pressurized NETWORK version.

•   Cableado para la versión a presión de la RED.
•  Câblage pour la version pressurisée de RÉSEAU.
•  Verdrahtung für unter Druck gesetzte NETZ-Version.
•  Fiação para a versão pressurizada da REDE.
•  Collegamenti per la versione pressurizzata della RETE.

A

B

C

D

E

F

G

H

R

J

K

L

M

N

P

U

T

S

NC

Alarm Common

Alarm In 3

Alarm In 2

Alarm In 1

NC

NC

White/Green

Heater /Blower

Heater /Blower

Camera Power

Camera Power

Orange

White/Orange 

Green

NC

NC

Wiring Chart Non-Pressurized Receiver Version

A. 

 

Heater 

 

 

           24VAC                 115VAC

  1) 

Red - Heater 1

  2) 

N/C 

 

            2.4A                      .5A

  3) 

Red - Heater

B. Camera Power 

 

          (58W)                    (58W)

  1) 

Black - V2   

           1.5A                      .3A 

 

 

  

  2) 

Orange - V1

C. Lens 

ANALOG/ IP 

          (36W)                    (36W)

  1) 

 Blue - Alarm Input 1

  2) 

 Violet - Alarm Input 2

  3) 

 Gray - Alarm Input 3

  4) 

 White - Alarm common

D.  Pan/Tilt 
  1) 

Gray - RXA

  2) 

Pink - N/C

  3) 

 Tan - TXA

  4) 

Green - RXB

  5) 

Brown - N/C

  6) 

Blue - TXB

E. BNC 

1(NETWORK IP)

F. Green Housing Ground (not shown)

Wiring for DDW10CR.

•  Cableado para DDW10CR.

•  Câblage pour DDW10CR.

•  Verdrahtung für DDW10CR.

•  Fiação para DDW10CR.

•  Collegamenti per DDW10CR.

2 1

4 3

1

2

3 2 1

6 5 4

A

B

C

D

E

1

2

3

or

5

6

7

8

Summary of Contents for DeputyDome DDW10CR1

Page 1: ...Bullet Resistant Outdoor dome PTZ Camera System with 26x Day Night Camera onboard receiver driver 120Vac heater Tough enough to stop a 9mm bullet PDDW10CR1 Pressurized Version DeputyDome Series 10 ga...

Page 2: ...onents can be damaged if improperly handled or dropped If an item appears to have been damaged in shipment replace it properly in its carton and notify the shipper Be sure to save 1 The shipping carto...

Page 3: ...pect to any Product requiring service during the warranty period which is subjected to any of the following abuse improper use negligence accident lightning damage or other acts of God i e hurricanes...

Page 4: ...bturateur lectronique 22 tapes DDW10CR1 N 115 VAC 90 VA 0 8 Amps DDW10CR2 N 24 VAC Kategorie 2 90 VA 3 75Amps KAMERA SPEZIFIKATIONEN Entschlie ung 470 TVL NTSC 460TVL PAL Minimale Ablichtung 1 0 1 0 L...

Page 5: ...gire a carca a no sentido hor rio para remover a carca a da montagem A montagem da parede pode agora ser unida parede Allenti tutti i dadi della flangia e giri l alloggiamento in senso orario per rimu...

Page 6: ...de r cepteur PDDW10CR2 Verdrahtung f r unter Druck gesetztes Empf ngermodell PDDW10CR2 Fia o para o modelo pressurizado do receptor PDDW10CR2 Collegamenti per il modello pressurizzato della ricevente...

Page 7: ...ur supprimer Pan Tilt rmove montage du d me et doublure So entfernen Sie Pan Tilt rmove Montage der Kuppel und Linienkonferenzen Para remover Pan Tilt rmove montagem da c pula e forro Per rimuovere Pa...

Page 8: ...inserire e installare cupola O Ring Align If Lanyard attaches to both trim ring and the outside of the housing Si Lanyard concede a ambos y el anillo exterior de la vivienda Si Lanyard attache la fois...

Page 9: ...ponga il mandrino dell aria sulla valvola del carro armato e cominci a riempirsi fino a che la valvola limitatrice della pressione non si apra Open the relief valve Drain all air from the housing and...

Page 10: ...G SETTINGS FOR RECEIVER DRIVER UNITS DIPSWITCHES The dipswitches serve a dual purpose First they control the address of the pan tilt when operated via RS485 Second they control the alarm and display f...

Page 11: ...n tilt zoom focus and backlight settings at the highest available speed Autotour Preset Number Function 79 Record Run Pattern 2 80 Record Run Pattern 1 81 Stop Recording Pattern 1 or 2 84 Reset the Ca...

Page 12: ...40 92 WSTH02 8 Star washer 5 41 30 VL1411 DDWC10 P T bracket 1 Part Number Description Qty 42 60 1414 DDWC10 pan limits collars 2 43 92 WSFL01 1 4 Flat washer SS 4 44 92 WSSL01 1 4 Split lockwasher SS...

Page 13: ...40 39 38 37 36 35 57 56 55 54 53 67 66 65 64 63 62 61 60 59 58 70 69 68 79 78 77 76 75 52 51 50 49 48 47 46 45 44 43 42 41...

Page 14: ...later than 20ms after the last byte of the message has been received If the message is not understood by the DeputyDome a NACK message will be sent If an inquiry message is successfully received from...

Page 15: ...s Assignment Message This six byte command sets the address of the dome The address is in hexadecimal and is contained in bytes 4 and 5 If the address is set to FFH then the unit derives its address f...

Page 16: ...t 01 and byte number five is the message terminator byte FUNCTION Byte 3 Byte 4 DESCRIPTION REQUEST POSITION P Get position ASCII character upper case p followed by the character The response to this...

Page 17: ...on data 9 F0 LS nibble 30H 3FH Position data is 30H ored with data nibble F03 F02 F01 F00 of lens focus position data 10 Terminator and Checksum 80H 8FH Most significant nibble is always 8 Least signi...

Page 18: ...he camera commands control parameters of camera operation All the Camera commands generate a Latch Status response message FUNCTION Byte 3 Byte 4 DESCRIPTION MANUAL IRIS TOGGLE L M Toggles iris operat...

Page 19: ...n in the table below BYTE DATA DESCRIPTION 1 F8H Autobaud character 2 Address in hex Camera address 01H DFH 3 S Upper case S 4 P1 MS nibble 30H 3FH Pressure data is 30H ored with data nibble P07 P06 P...

Page 20: ...ousings Poles Power Supplies and Accessories and 5 Years on camera systems SView QView Warriors and InfraRed Illuminators Register Your ProductsOnline Take a few moments and validate your purchase via...