Moog Videolarm DeputyDome DDW10CR1 Installation And Operation Instructions Manual Download Page 10

Address         SW1           SW2            SW3         SW4        SW5          SW6

Address           SW1          SW2            SW3         SW4         SW5         SW6

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18

Off                On                  On               On            On               On           
On                Off                  On               On            On               On           
Off                Off                  On               On            On               On           
On                On                  Off               On            On               On           
Off                On                  Off               On            On               On           
On                Off                  Off               On            On               On           
Off                Off                  Off               On            On               On           
On                On                  On               Off            On               On           
Off                On                  On               Off            On               On           
On                Off                  On               Off            On               On           
Off                Off                  On               Off            On               On           
On                On                  Off               Off            On               On           
Off                On                  Off               Off            On               On           
On                Off                  Off               Off            On               On           
Off                Off                  Off               Off            On               On           
On                On                  On               On            Off               On           
Off                On                  On               On            Off               On           
On                Off                  On               On            Off               On           

Off              Off                  On               On              Off             On           
On              On                  Off               On              Off             On           
Off              On                  Off               On              Off             On           
On              Off                  Off               On              Off             On           
Off              Off                  Off               On              Off             On           
On              On                  On               Off              Off             On           
Off              On                  On               Off              Off             On           
On              Off                  On               Off              Off             On           
Off              Off                  On               Off              Off             On           
On              On                  Off               Off              Off             On           
Off              On                  Off               Off              Off             On           
On              Off                  Off               Off              Off             On           
Off              Off                  Off               Off              Off             On           

CHANGING SETTINGS FOR  RECEIVER / DRIVER UNITS

DIPSWITCHES

The dipswitches serve a dual purpose.  First, they control the address of the pan/tilt when operated via RS485.  Second, they control the alarm and display 
functions for the pan/tilt. Address changes are made using the dip switches located on the PC board.

Dipswitches

UNIT ADDRESSES FOR 485 CONTROL

The dipswitches come factory preset with switch 6 in the on position, indicating the address mode. The default address for the pan/tilt on receiver/driver versions of the DeputyDome™ is 
preset at the factory as "1." If more than one unit is being used with 485 control it will be necessary to change the address for each additional unit.  

To change the address, power down the unit, remove the pan/tilt from the housing, and set the address using the dipswitch settings shown in Chart 1 in the next column. Replace the 
unit and power up.

CHART 1 - RECEIVER/DRIVER PAN/TILT ADDRESSES

19
20
21
22
23
24
25
26
27
28
29
30
31

21

22

Summary of Contents for DeputyDome DDW10CR1

Page 1: ...Bullet Resistant Outdoor dome PTZ Camera System with 26x Day Night Camera onboard receiver driver 120Vac heater Tough enough to stop a 9mm bullet PDDW10CR1 Pressurized Version DeputyDome Series 10 ga...

Page 2: ...onents can be damaged if improperly handled or dropped If an item appears to have been damaged in shipment replace it properly in its carton and notify the shipper Be sure to save 1 The shipping carto...

Page 3: ...pect to any Product requiring service during the warranty period which is subjected to any of the following abuse improper use negligence accident lightning damage or other acts of God i e hurricanes...

Page 4: ...bturateur lectronique 22 tapes DDW10CR1 N 115 VAC 90 VA 0 8 Amps DDW10CR2 N 24 VAC Kategorie 2 90 VA 3 75Amps KAMERA SPEZIFIKATIONEN Entschlie ung 470 TVL NTSC 460TVL PAL Minimale Ablichtung 1 0 1 0 L...

Page 5: ...gire a carca a no sentido hor rio para remover a carca a da montagem A montagem da parede pode agora ser unida parede Allenti tutti i dadi della flangia e giri l alloggiamento in senso orario per rimu...

Page 6: ...de r cepteur PDDW10CR2 Verdrahtung f r unter Druck gesetztes Empf ngermodell PDDW10CR2 Fia o para o modelo pressurizado do receptor PDDW10CR2 Collegamenti per il modello pressurizzato della ricevente...

Page 7: ...ur supprimer Pan Tilt rmove montage du d me et doublure So entfernen Sie Pan Tilt rmove Montage der Kuppel und Linienkonferenzen Para remover Pan Tilt rmove montagem da c pula e forro Per rimuovere Pa...

Page 8: ...inserire e installare cupola O Ring Align If Lanyard attaches to both trim ring and the outside of the housing Si Lanyard concede a ambos y el anillo exterior de la vivienda Si Lanyard attache la fois...

Page 9: ...ponga il mandrino dell aria sulla valvola del carro armato e cominci a riempirsi fino a che la valvola limitatrice della pressione non si apra Open the relief valve Drain all air from the housing and...

Page 10: ...G SETTINGS FOR RECEIVER DRIVER UNITS DIPSWITCHES The dipswitches serve a dual purpose First they control the address of the pan tilt when operated via RS485 Second they control the alarm and display f...

Page 11: ...n tilt zoom focus and backlight settings at the highest available speed Autotour Preset Number Function 79 Record Run Pattern 2 80 Record Run Pattern 1 81 Stop Recording Pattern 1 or 2 84 Reset the Ca...

Page 12: ...40 92 WSTH02 8 Star washer 5 41 30 VL1411 DDWC10 P T bracket 1 Part Number Description Qty 42 60 1414 DDWC10 pan limits collars 2 43 92 WSFL01 1 4 Flat washer SS 4 44 92 WSSL01 1 4 Split lockwasher SS...

Page 13: ...40 39 38 37 36 35 57 56 55 54 53 67 66 65 64 63 62 61 60 59 58 70 69 68 79 78 77 76 75 52 51 50 49 48 47 46 45 44 43 42 41...

Page 14: ...later than 20ms after the last byte of the message has been received If the message is not understood by the DeputyDome a NACK message will be sent If an inquiry message is successfully received from...

Page 15: ...s Assignment Message This six byte command sets the address of the dome The address is in hexadecimal and is contained in bytes 4 and 5 If the address is set to FFH then the unit derives its address f...

Page 16: ...t 01 and byte number five is the message terminator byte FUNCTION Byte 3 Byte 4 DESCRIPTION REQUEST POSITION P Get position ASCII character upper case p followed by the character The response to this...

Page 17: ...on data 9 F0 LS nibble 30H 3FH Position data is 30H ored with data nibble F03 F02 F01 F00 of lens focus position data 10 Terminator and Checksum 80H 8FH Most significant nibble is always 8 Least signi...

Page 18: ...he camera commands control parameters of camera operation All the Camera commands generate a Latch Status response message FUNCTION Byte 3 Byte 4 DESCRIPTION MANUAL IRIS TOGGLE L M Toggles iris operat...

Page 19: ...n in the table below BYTE DATA DESCRIPTION 1 F8H Autobaud character 2 Address in hex Camera address 01H DFH 3 S Upper case S 4 P1 MS nibble 30H 3FH Pressure data is 30H ored with data nibble P07 P06 P...

Page 20: ...ousings Poles Power Supplies and Accessories and 5 Years on camera systems SView QView Warriors and InfraRed Illuminators Register Your ProductsOnline Take a few moments and validate your purchase via...

Reviews: