Moog Videolarm DeputyDome DDW10CR1 Installation And Operation Instructions Manual Download Page 14

VL-422 Communication Protocol (DeputyDome)

Message Format

Data is transmitted at 9600 baud, 1 start bit, 1 stop bit, 8 data bits (lsb first), no parity. The general format for messages sent to the DeputyDome and for inquiry response messages 
sent by the DeputyDome is shown below:

BYTE

DATA

DESCRIPTION

1

F8H

Sync character

2

Address in hex

Camera address (01H – DFH)

3 to N-1

Command Data

All command characters are 8-bit characters; most are ASCII characters.

N

Terminator and Checksum

80H - 8FH   Most significant bit is always 1.  Least significant (LS) nibble is XOR of all previous bytes (LS 
nibble only) except for the leading character F8H.

The acknowledge message sent from the DeputyDome shall consist of a single hexadecimal 06 character. The negative acknowledge message shall consist of a single hexadecimal 
15 character. Characters enclosed in quotes represent ASCII characters and numbers followed by an “H” are hexadecimal numbers.

Message Sequence

Each message transaction is initiated by the controller. The DeputyDome shall respond to each successfully received message with an ACK message no sooner than 1ms. and no 
later than 20ms. after the last byte of the message has been received. If the message is not understood by the DeputyDome, a NACK message will be sent. 

If an inquiry message is successfully received from the host, the DeputyDome shall respond with the ACK message as previously described and the inquiry response shall then be 
transmitted no sooner than 1ms. and no later than 100ms. after the transmission of the ACK.

Command Messages

These commands control the basic motion of the pan/tilt platform and the lens movement of the camera system. Byte number 1 is the start of message F8, byte 
number 2 is the device address (default = 01), and byte number five is the message terminator byte.

3.1 

Motion Command Messages

FUNCTION

Byte #3

Byte #4

DESCRIPTION

PAN LEFT

“P”

“L”

Move at default speed.

PAN RIGHT

“P”

“R”

Move at default speed.

PAN STOP

“P”

“S”

TILT UP

“T”

“U”

Move at default speed.

TILT DOWN

“T”

“D”

Move at default speed.

TILT STOP

“T”

“S”

ZOOM IN

“Z”

“I”

Zoom In (Telephoto)

ZOOM OUT

“Z”

“O”

Zoom Out (Wide angle)

ZOOM STOP

“Z”

“S”

FOCUS NEAR

“F”

“N”

FOCUS FAR

“F”

“F”

FOCUS STOP

“F”

“S”

IRIS OPEN

“I”

“O”

IRIS CLOSE

“I”

“C”

IRIS STOP

“I”

“S”

PAN LEFT AT SPEED “x”

“l”

“0” - “?”

Pan left at speed index 0-15.  (“l” is lower-case “L”.)

PAN RIGHT AT SPEED “x”

“r”

“0” - “?”

Pan right at speed index 0-15.

TILT UP AT SPEED “x”

“u”

“0” - “?”

Tilt up at speed index 0-15.

TILT DOWN AT SPEED “x”

“d”

“0” – “?”

Tilt down at speed index 0-15.

Summary of Contents for DeputyDome DDW10CR1

Page 1: ...Bullet Resistant Outdoor dome PTZ Camera System with 26x Day Night Camera onboard receiver driver 120Vac heater Tough enough to stop a 9mm bullet PDDW10CR1 Pressurized Version DeputyDome Series 10 ga...

Page 2: ...onents can be damaged if improperly handled or dropped If an item appears to have been damaged in shipment replace it properly in its carton and notify the shipper Be sure to save 1 The shipping carto...

Page 3: ...pect to any Product requiring service during the warranty period which is subjected to any of the following abuse improper use negligence accident lightning damage or other acts of God i e hurricanes...

Page 4: ...bturateur lectronique 22 tapes DDW10CR1 N 115 VAC 90 VA 0 8 Amps DDW10CR2 N 24 VAC Kategorie 2 90 VA 3 75Amps KAMERA SPEZIFIKATIONEN Entschlie ung 470 TVL NTSC 460TVL PAL Minimale Ablichtung 1 0 1 0 L...

Page 5: ...gire a carca a no sentido hor rio para remover a carca a da montagem A montagem da parede pode agora ser unida parede Allenti tutti i dadi della flangia e giri l alloggiamento in senso orario per rimu...

Page 6: ...de r cepteur PDDW10CR2 Verdrahtung f r unter Druck gesetztes Empf ngermodell PDDW10CR2 Fia o para o modelo pressurizado do receptor PDDW10CR2 Collegamenti per il modello pressurizzato della ricevente...

Page 7: ...ur supprimer Pan Tilt rmove montage du d me et doublure So entfernen Sie Pan Tilt rmove Montage der Kuppel und Linienkonferenzen Para remover Pan Tilt rmove montagem da c pula e forro Per rimuovere Pa...

Page 8: ...inserire e installare cupola O Ring Align If Lanyard attaches to both trim ring and the outside of the housing Si Lanyard concede a ambos y el anillo exterior de la vivienda Si Lanyard attache la fois...

Page 9: ...ponga il mandrino dell aria sulla valvola del carro armato e cominci a riempirsi fino a che la valvola limitatrice della pressione non si apra Open the relief valve Drain all air from the housing and...

Page 10: ...G SETTINGS FOR RECEIVER DRIVER UNITS DIPSWITCHES The dipswitches serve a dual purpose First they control the address of the pan tilt when operated via RS485 Second they control the alarm and display f...

Page 11: ...n tilt zoom focus and backlight settings at the highest available speed Autotour Preset Number Function 79 Record Run Pattern 2 80 Record Run Pattern 1 81 Stop Recording Pattern 1 or 2 84 Reset the Ca...

Page 12: ...40 92 WSTH02 8 Star washer 5 41 30 VL1411 DDWC10 P T bracket 1 Part Number Description Qty 42 60 1414 DDWC10 pan limits collars 2 43 92 WSFL01 1 4 Flat washer SS 4 44 92 WSSL01 1 4 Split lockwasher SS...

Page 13: ...40 39 38 37 36 35 57 56 55 54 53 67 66 65 64 63 62 61 60 59 58 70 69 68 79 78 77 76 75 52 51 50 49 48 47 46 45 44 43 42 41...

Page 14: ...later than 20ms after the last byte of the message has been received If the message is not understood by the DeputyDome a NACK message will be sent If an inquiry message is successfully received from...

Page 15: ...s Assignment Message This six byte command sets the address of the dome The address is in hexadecimal and is contained in bytes 4 and 5 If the address is set to FFH then the unit derives its address f...

Page 16: ...t 01 and byte number five is the message terminator byte FUNCTION Byte 3 Byte 4 DESCRIPTION REQUEST POSITION P Get position ASCII character upper case p followed by the character The response to this...

Page 17: ...on data 9 F0 LS nibble 30H 3FH Position data is 30H ored with data nibble F03 F02 F01 F00 of lens focus position data 10 Terminator and Checksum 80H 8FH Most significant nibble is always 8 Least signi...

Page 18: ...he camera commands control parameters of camera operation All the Camera commands generate a Latch Status response message FUNCTION Byte 3 Byte 4 DESCRIPTION MANUAL IRIS TOGGLE L M Toggles iris operat...

Page 19: ...n in the table below BYTE DATA DESCRIPTION 1 F8H Autobaud character 2 Address in hex Camera address 01H DFH 3 S Upper case S 4 P1 MS nibble 30H 3FH Pressure data is 30H ored with data nibble P07 P06 P...

Page 20: ...ousings Poles Power Supplies and Accessories and 5 Years on camera systems SView QView Warriors and InfraRed Illuminators Register Your ProductsOnline Take a few moments and validate your purchase via...