background image

3

English

Do not block the mist outlet.

Use clean water only.

Do not use hot water.

Never put aroma oil or other fragrances into the water tank.

Do not use the product by placing it directly onto a carpet or other 
object with soft fibers.

When cleaning the product, do not use household detergent, thinner, 
benzene, alcohol or a polishing powder.

When unplugging the power cord, always unplug by grasping the 
power plug, not by pulling on the power cord.

Replace the water in the water tank and water tub with new water 
everyday. Clean regularly to ensure that the inside of the product is 
always clean.

Do not place cell phones, computers, or other electronic devices near 
the product.

Because the area around the humidifier can become very humid when operating, do not 
place cell phones, computers or other electronic devices that are sensitive to humidity near the 
humidifier.

Be careful that the product does not freeze.

If the product is placed in a location subject to freezing temperatures, throw away the water 
inside.

Place the product in a location that is at least two meters away from 
televisions, radios, and other electronics.

Otherwise, static interference can result.

Do not tilt the product.

This appliance is not intended for use by persons (including children) 
with reduced physical, sensory or mental capabilities, or lack of 
experience and knowledge, unless they have been given supervision 
or instruction concerning use of the appliance by a person responsible 
for their safety.

Children should be supervised to ensure that they do not play with the 
appliance.

If the supply cord is damaged, it must be replaced by the manufacturer, 
its service agent or similarly qualified persons in order to avoid a hazard.

01̲MOD-KH1101EU.indb   3

01̲MOD-KH1101EU.indb   3

2014/07/11   21:51:15

2014/07/11   21:51:15

Summary of Contents for MOD-KH1101EU

Page 1: ......

Page 2: ...n burns injury or electrical shock Do not insert metal objects such as pins wires or other foreign objects inside the gaps in the product This can result in an electrical shock or injury After use be...

Page 3: ...electronic devices that are sensitive to humidity near the humidifier Be careful that the product does not freeze If the product is placed in a location subject to freezing temperatures throw away the...

Page 4: ...human health from uncontrolled waste disposal recycle it responsibly to promote the sustainable reuse of material resources To return your used device please use the return and collection systems or...

Page 5: ...passage cover Heater If the water passage cover is not attached correctly hot water can overflow from the humidifier body Insert the legs at the bottom of the water passage cover dotted line section...

Page 6: ...flow sensor Water drain direction arrow indicator Mist hole Water tank cap Water tank back side Accessories Ceramic disc set IMM DISC001 Ceramic disc Special tool Replacement ceramic disc set IMM DISC...

Page 7: ...the arrow Draining the water in a different direction may let water get into the fan outlet and can result in malfunction Overflow sensor An overflow occurs when the water level is excessively high Th...

Page 8: ...ifier water drops inside the cover will spill when removing the cover Therefore have towels on hand so the humidifier and floor do not get wet Set the water tank into the humidifier so that it fits se...

Page 9: ...perates mood lamp lights humidifier operates mood lamp turns off operation stops Turning off the mood lamp 2 If you press the Power button again the mood lamp turns off The humidifier continues operat...

Page 10: ...ss the Mist Setting button to set the mist level and the Timer Setting button to enable timer settings Setting the mist level 1 To set the mist level press the Mist Setting button Each time the button...

Page 11: ...evel in the water tank is low When the water level in the water tank and water tub get low the alarm makes a sound with five beeps and the Power Water indicator P E lights up red After draining any wa...

Page 12: ...il Tab Place the felt under the tabs so it does not stick up from the indentation in the aroma case If it sticks up it could get caught when inserting removing the felt case Starting operation 3 To st...

Page 13: ...could occur After cleaning be sure to always remount the parts in their original locations Otherwise an injury or malfunction could result Cleaning the Hybrid Humidifier at least twice a week Fully d...

Page 14: ...he product is always clean Use without regular cleaning will cause buildup of dirt and grime which will lead to growing of mold and bacteria resulting in unpleasant odors In certain cases this could c...

Page 15: ...front side and back side Mount with the front side facing upward Humidifier Special tool Ceramic disc set IMM DISC001 Ring holder Ceramic disc Rubber ring Ceramic disc Remove the rubber ring Front Bac...

Page 16: ...is heated to at least 60 C for sterilization before starting the misting operation The ceramic disc must be replaced Replace the ceramic disc See page 14 The Power Water indicator P E is lit red even...

Page 17: ...pprox 11 hrs in High mode H Tank capacity Approx 2 000 ml Power cord length Approx 1 8 m External dimensions 200 mm Dia 260 mm H Weight Approx 1 3 kg body only Accessories User s Manual 1 Replacement...

Page 18: ......

Reviews: