5. Setting up the device
Menu level
Parameterization level
Min/max-value inquiry - assignment of key functions,
Default:
Here, you can enter for the operating mode either a min/max-value inquiry or a
threshold value correction on the arrow keys.
If the min/max-memory is activated with
, the measured min/max-values will
be saved during operation and can be called up via the arrow keys
[▲] [▼].
When
the device is restarted or the buttons are pressed simultaneously, the values are
lost or deleted. If the threshold value correction
is selected, the limit values can
be changed during operation without hindering the operating procedure.
With
the display is tared to zero and is saved permanently as offset. The
device confirms the correct taring by showing
in the display. If
is
parameterized, the navigation keys
[▼] [▲]
have no function in operating mode.
Flashing of display,
Default:
Here, flashing of the display can be added as an extra alarm function, either to the
first limit value (select:
), the second limit value (select:
) or to both limit
values (select:
). With
(works setting), no flashing is assigned at all.
Limit values / limits,
Default:
For both limit values, two different values can be parameterized. With this, the
parameters for each limit value are called up one after the other.
Hysteresis for limit values,
Default:
For both limit values, a hysteresis function exists that reacts according to the
functional principle (operating current / quiescent current).