Page
XG0204 04/05
Panorama Direct Vented Fireplace
Installation
Wiring
Figure 15b.
Fan wiring schematic.
Gas Control and Pilot Wiring
Honeywell (Q3450)
Pilot Assembly
Pilot Electrical
Harness Connector
Honeywell Gas
Control (SV9501M)
Gas Control
Connector
Fuse
Limit
Switch
Wall
Switch
Fan Plug
Receptacle
Junction Box
Junction Box Cover
White
Black
Green
40 VA
Transformer
115VAC
24VAC
Grnd Screw
Figure 14.
Wiring for the M38DV-PRC-I with Honeywell gas control
and pilot.
Figure 15a.
Fan wiring.
NOTE:
If any of the original wire supplied with the appli-
ance is replaced, it must be replaced with the same
type, or its equivalent.
Fan Wiring
The M38DV-PRC is equipped with 4 fans for circulating heat into the
living space.
Installations in Canada
must be in accordance with
CSA C22.1
Canadian Electrical Code Part 1 and/or Local Codes.
Installations in the USA
must be in accordance with local codes
or, in the absence of local codes, with the National Electrical Code,
ANSI/NFPA 70-1987.
Fan Switch
M38DV-
Removing and Installing the In-
ner Doors
Door Removal
The inner (combustion) doors are located behind the outer decorative
doors. To remove the inner doors, simply unscrew the nine (9) ma-
chine screws on the top, bottom and side of the door.
(See figure 16).
Door Installation
To attach the inner doors, align the door with the screw holes and
re-fasten with all nine machine screws. Ensure that a good seal is
maintained.
Figure 16.
Removing inner doors.
115/1/60 Supply
G
L1 L2
Fan Switch
G
L2-WH
L1-BLK
Quick Connect
plug to motor