Page 16
XG0219 - 080421
Installation
Finishing
Standalone
12" MIN
FRAMING
FINISHING MATERIAL
WALL BOARD
P42VFO
FLOORING
Extend vertical beams of wood to show that its a wall
Change to wood instead of marble
Separate drawing for framing with dimensions for the opening, depth also
Add sheet to show dimensions of framing only
Another sheet view with just the fireplace in the framing pointing out the holes for screwing to wood
1:17
SIZE DWG. NO.
A
REV.
SHEET 1 OF 3
WEIGHT:
P42VFO WALL INSTALLATION
FINISH
MATERIAL
DIMENSIONS ARE IN INCHES
TOLERANCES:
FRACTIONAL 1/32"
TWO PLACE DECIMAL .015"
THREE PLACE DECIMAL .005"
ALL BENDS ARE ASSUMED
TO BE 90 UNLESS NOTED
OTHERWISE.
CHECKED BY
DRAWN BY
TMC
DATE
NAME
15-Aug-16
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF CANADIAN HEATING PRODUCTS. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF CANADIAN HEATING PRODUCTS IS PROHIBITED.
PROPRIETARY AND CONFIDENTIAL
\\pdm\shared$\Products\Residential Products\R&D Projects\PL42VO
\Cad Drawings\MANUAL VIEWS\WALL\P42VFO WALL INSTALLATION
August-15-16 10:47:52 AM
SCALE
Figure 27
In the wall finishing
FRAMING
P42VFO
WALL BOARD/FINISHING MTL
12"
MIN
DRAINAGE HOLES
(BOTH SIDES)
1:18
SIZE DWG. NO.
A
REV.
SHEET 1 OF 3
WEIGHT:
STAND ALONE
FINISH
MATERIAL
DIMENSIONS ARE IN INCHES
TOLERANCES:
FRACTIONAL 1/32"
TWO PLACE DECIMAL .015"
THREE PLACE DECIMAL .005"
ALL BENDS ARE ASSUMED
TO BE 90 UNLESS NOTED
OTHERWISE.
CHECKED BY
DRAWN BY
TMC
DATE
NAME
15-Aug-16
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF CANADIAN HEATING PRODUCTS. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF CANADIAN HEATING PRODUCTS IS PROHIBITED.
PROPRIETARY AND CONFIDENTIAL
\\pdm\shared$\Products\Residential Products\R&D Projects\PL42VO
\Cad Drawings\MANUAL VIEWS\STAND ALONE\STAND ALONE
August-15-16 2:16:01 PM
SCALE
Figure 28
Standalone Finishing
In The Wall Installation
Fireplace Facing
When sizing the finish material
for your fireplace, it is important
to remember the following:
THE OPENING MUST NOT BE
OBSTRUCTED IN ANY WAY - to
do so restricts the air supply for
the control compartments and
heat exchanger it also prevents
access for servicing controls.
Decorative facing must not
extend past the fireplace
opening, because it will interfere
with the access to retainers
for removal of glass door and
restrict airflow into the unit.
*
12" minimum above grade is for
US installations only
*
*
Framing
Framing
Fireplace
Fireplace
Flooring
Drainage holes
(both sides)
Wall board/Finishing material
Finishing material
Wall board