E38-PV Gas Fireplace
Part No. XM0500
Installation
Right or Left V
Right or Left V
Right or Left V
Right or Left V
Right or Left Vent Exhaust
ent Exhaust
ent Exhaust
ent Exhaust
ent Exhaust
The fireplace may ventout the right or left hand side. To convert:
1. Lift off upper housing cover.
2. Disconnect flexible vent from the venter motor.
3. Remove the four(4) machine screws that hold the venter motor
secure and rotate the motor 180° . Replace & tighten the four(4)
machine screws to secure the motor in place.
4. Remove the four(4) sheet metal screws that hold the
fan plate
secure. Remove the four(4) sheet metal screws that hold the
vent
exhaust plate
secure. Reverse the two plates and re-install all
screws. Ensure that the screws are tightened properly.
5. Re-connect the flexible vent, ensure that a goodconnection is
made.
6. Replace upper housing cover.
Upper housing cover
Flexible vent
Vent exhaust plate
4 x Machine screws
Venter motor
Figure 8.
Right hand exhaust.
Figure 9.
Left hand exhaust
Venter Motor
4 x Machine screws
Flexible vent
Upper housing cover
Vent Installation
Installation Requirements
n
E38-PV fireplaces are certified for use with Montigo
Power Vent
components and
Standard Series
(4" / 7") venting components
n
0" clearance to combustibles
for vent pipes
n
Use only
certified Montigo vent components.
(Use of other parts
will void the Montigo warranty, and may impede the operation of
the fireplace.)
n
All joints must be secured with a minimum of two screws per joint
and sealed with high temp silicone
n
The exhaust portion of avent termination must not be recessed in
walls or siding
n
Horizontal runs with solid pipe must be supported by a minimum
of two supports per horizontal run. A minimum of one screw on
each side of support is also required
n
Flex vent sections may be stretched up to twice their compressed
length (i.e. a 6' section may be stretched to 12')
Figure 10.
Typical vent configurations.
7 1/2
7 1/2
Max. Vent length: 60 feet
Min. Vent length: 3 feet
7" flex vent requires
min. opening of 7 1/2" x 7 1/2"
Left or right exhaust
0" Clearance
to combustibles
for venting
Std. MTO
termination
Power vent drop
termination