background image

Page 11

Page 11

Page 11

Page 11

Page 11

E38-PV Gas Fireplace

Part No. XM0500

For Your Safety - READ BEFORE LIGHTING:

To Turn Off Gas To Appliance:

Lighting Instructions:

n

If you cannot reach your gas supplier, call the Fire
Department.

C.

Use only your hand to push in or turn the gas control knob.
Never use tools. If  the knob will not push in or turn by
hand, don't try to repair it, call a qualified service
technician. Force or attempt to repair may result in a fire or
explosion.

D.

Do not use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect
the appliance and to replace any part of the control system,
and any gas control which has been under water.

A.

This appliance is equipped with an ignition system that
lights the pilot burner automatically. 

Do not attempt to

light the pilot by hand.

B. BEFORE LIGHTING

 smell all around the appliance area

for gas.  Be sure to smell next to the floor because some
gas is heavier than air and will settle on the floor.

What To Do If You Smell Gas:

n

Do not try to light any appliance.

n

Do not touch any electrical switch; do not use any
phone in your building.

n

Immediately call your gas supplier from a neighbour's
phone. Follow the gas supplier's instructions.

1.

Turn off remote switch.

2.

Flip down lower brass trim.

3.

Turn the switch on the gas control to "Off".

4.

Flip up brass trim.

1. STOP!  

Read the safety information above on this label.

2.

Flip down lower brass trims.

3.

Turn switch on the gas control to OFF".

4.

Wait 5 minutes to clear out any gas.  If you smell gas,

STOP! 

Follow "B" in the safety information above on this

label.  If you don't smell gas, go to the next step.

5.

Turn switch on the gas control to "ON".

 NOTE:

 This unit is

equipped with an ignition system that lights the pilot burner

automatically. 

Do not attempt to light the pilot by hand.

6.

Turn on wall switch.

7.

Flip up lower brass trim.

8.

If the fireplace does not operate, follow the instructions "To

Turn Off Gas To Appliance" and call your service technician

or gas supplier.

with Honeywell  Intermittent  Pilot

WARNING:

WARNING:

WARNING:

WARNING:

WARNING:

If you do not follow these instructions exactly, a fire or explosion
may result causing property damage, personal injury or loss of life.

Operation

Gas

Inlet

Gas Control Switch
Shown in "On" Position

Summary of Contents for E38-PV

Page 1: ... Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Warning Improper installation adjustment alteration serviceormaintenancecancause injury or property damage Refer to this manual For assistance or additional informat...

Page 2: ...ode Part 1 and or Local Codes Installations in the USA must conform to local codes or in the absense of local codes to the National Fuel Gas Code ANSI Z223 1 1988 The appliance must be grounded in accordance with local codes or in the absence of local codes with the National Electrical Code ANSI NFPA 70 1987 Table Of Contents Introduction 2 Installation Installing the Fireplace Shell 3 Installing ...

Page 3: ...to the fireplace opening must not project beyond the shaded area shown in Figure 19b For protection against freezing temperatures it is recommended that outer walls of the chase be insulated with a vapour barrier This will reduce the possibility of a cold air convection current on the fireplace Top View Front View Side View Clearances The E38 PV clearances to combustible materials are Top 1 Back 0...

Page 4: ...psig 3 5 kPa The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psig 3 5 kPa Installing The Remote Switch The E38 PV s gas valve located behind the lower brass trim may be connected to a wall switch or a hand held remote The valve oper...

Page 5: ...tion Before installing the termination or venting check to ensure the planned termination location is acceptable For a detailed illustration of allowed termination locations see Appendix B 11 11 Installing Power Vent Reverse Terminations When terminating a vent run below a soffit or an overhang use the Drop Termination to increase the clearance between the termination and the finish materials 1 Fr...

Page 6: ...hand exhaust Figure 9 Left hand exhaust Venter Motor 4 x Machine screws Flexible vent Upper housing cover Vent Installation Installation Requirements n E38 PV fireplaces are certified for use with Montigo Power Vent components and Standard Series 4 7 venting components n 0 clearance to combustibles for vent pipes n Use only certified Montigo vent components Use of other parts will void the Montigo...

Page 7: ... feet to prevent the vent from sagging 6 Maximum 60 feet of vent allowed with 4 x 90 bends 7 The flexible vent is tested for 0 clearance to combustibles Allowable number of 90 Bends per vent length Length of 90 Bends 60 feet 4 x 90 45 feet 4 x 90 30 feet 5 x 90 25 feet 5 x 90 20 feet 6 x 90 Example 25 feet of flexible vent length would allow the use of five 5 90 degree elbows NOTES All dimension l...

Page 8: ...t A Magnet Pull bottom of door surround outwards and upwards Glass door frame Figure 13b Removing or installing the glass door Removing and Installing the Insert You may remove the insert to protect it from theft and damage during construction 1 Remove the two machine screws 1 left 1 right at the top of the insert that attach the insert to the shell See Figure12 Inset 1 2 Remove the 4 machine scre...

Page 9: ...A Log C Log B NOTES n If logs are not placed properly excessive sooting will result n The surface of the logs will crack due to the heat from the flames This is a normal occurance Figure 14a Wiring for optional air circulating fan kit G L1 WH L2 BLK Quick Connect plug to motor NOTE If any of the original wire supplied with the appliance is replaced it must be replaced with the same type or its equ...

Page 10: ...ngs Mantels Surrounds NOTE National Canadian Gas Association mantel test requirements are for fire hazard prevention to combustible materials New technology to meet consumer and government demands for the wise use of energy has prompted us to manufacture many models of fireplaces which are hot fuel and energy efficient Please be aware temperatures over the mantel will rise above normal room temper...

Page 11: ... try to light any appliance n Do not touch any electrical switch do not use any phone in your building n Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions 1 Turn off remote switch 2 Flip down lower brass trim 3 Turn the switch on the gas control to Off 4 Flip up brass trim 1 STOP Read the safety information above on this label 2 Flip down lower bras...

Page 12: ...s and liquids n Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water Cleaning When the fireplace is first activated there may be some smoking and a visible film may be left on the glass This is a normal condition and is the resu...

Page 13: ...correctly consult your dealer or the manufacturer All service and repairs should be performed by a qualified agency All spare parts optional fans and optional trim finishes are available from your local dealer or the manufacturer HONEYWELL SV 9500 SV9600 Troubleshooting Sequence NOTE Before Troubleshooting Familiarize Yourself With The Startup And Checkout Procedure Turn Gas Supply off Set thermos...

Page 14: ...or any other solid fuel will cause damage to the Gas Appliance will produce excessive temperatures and will result in a fire hazard Limitations On Liability Limitations On Liability Limitations On Liability Limitations On Liability Limitations On Liability It is expressly agreed and understood that The Companies sole obligation and purchaser s exclusive remedy under this Warranty under any other w...

Page 15: ...14 15 Available Options and Accessories 1 Add on Bay Window 2 Hand Held Remote Control 3 Variable Speed Blower Kit 4 2 Fan Kit 5 4 Fan Kit 6 4 Piece Picture Frame Surround PFS 7 3 Piece Picture Frame Surround PFO 8 Door Cover Square DF0 9 Door Cover Arched DFA 10 Horizontal Trim Kits Black Brass Nickel 11 Replacement Logset ...

Page 16: ...ations 12 12 12 18 Pitched Roof Flat Roof 18 12 Top Parapet Wall 12 Min to Ceiling RECESSED AREA 12 12 24 36 72 72 12 12 12 12 12 72 Service Regulator Vent Must be a solid Balcony Three Balcony Two 2 Unvented Soffit Termination of vent within outlined zone not permitted Gas Service Riser Grade 36 24 12 ...

Page 17: ...Page 17 Page 17 Page 17 Page 17 Page 17 E38 PV Gas Fireplace Part No XM0500 Notes ...

Page 18: ...Canadian Heating Products Inc Surrey BC V3W 2V6 Montigo Del Ray Corp Ferndale WA 98248 XG0500 Rev 00 01 99 ...

Reviews: