background image

 

 

DRAWER GASKET GUIDE 

Model Number 

 

Gasket (Small) 

15-3/4” Width 

Part #  

66422-7 

 

 

Gasket (Medium) 

23-3/4” Width  

Part # 

65539-2 

 

Gasket (Large) 

28-3/4” Width 

Part # 

60789-4 

RB-36-SC / FB-36-SC 

Qty: 2 

  

  

RB-36-R / FB-36-R 

  

  

Qty: 2 

RB-48-SC / FB-48-SC 

  

  

Qty: 2 

RB-48-R / FB-48-R 

Qty: 2 

Qty: 2 

  

RB-60-SC / FB-60-SC 

Qty: 2 

Qty: 2 

  

RB-60-R / FB-60-R 

  

Qty: 2 

Qty: 2 

RB-72-SC / FB-72-SC 

  

Qty: 2 

Qty: 2 

RB-72-R / FB-72-R 

  

  

Qty: 4 

RB-84-SC / FB-84-SC 

  

  

Qty: 4 

RB-84-R / FB-84-R 

  

Qty: 4 

Qty: 2 

RB-96-SC / FB-96-SC 

  

Qty: 4 

Qty: 2 

RB-96-R / FB-96-R 

  

  

Qty: 6 

RB-108-SC / FB-108-SC 

  

  

Qty: 6 

RB-108-R / FB-108-R 

  

Qty: 6 

Qty: 2 

NOTE:  PLEASE  REFER  TO  THIS  GUIDE  FOR  REPLACEMENT  GASKET  P/N’S  ON  ALL         
MODELS LISTED 

20 

Summary of Contents for FB-108-R

Page 1: ...PLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCE THE MONTAGUE COMPANY 1830 Stearman Avenue P O BOX 4954 Hayward CA 94540 4954 TEL 510 785 8822 FAX 510 785 3342 SERVICE MAINTENANCE MONTAGUE REFRIGERATED...

Page 2: ...RATURE PROBE ERROR B MANUAL DEFROST DIGITAL CONTROLLER LOW TEMP PAGE 7 A OPERATIONAL MODE B TEMPERATURE SET POINT C FREEZER DIFFERENTIAL DIGITAL CONTROLLER LOW TEMP PAGE 8 A DEFROST INTERVAL B DEFROST...

Page 3: ...HODS FOR CLEANING STAINLESS STEEL TROUBLESHOOTING PAGE 17 DRAWER CONFIGURATION PAGE 18 19 DRAWER GASKET GUIDE PAGE 20 REFER BASE WIRING DIAGRAM R SC PAGE 21 FREEZER BASE WIRING DIAGRAM R SC PAGE 22 CO...

Page 4: ...ssumes full responsibility for safe delivery upon acceptance of this shipment If shipment arrives damaged 1 VISIBLE LOSS OR DAMAGE Be certain this is noted on freight bill or express receipt and signe...

Page 5: ...r through a representative are engaged in and are responsible for The installation of electrical wiring from the electric meter main control box or service outlet to the electric appliance Qualified p...

Page 6: ...rated storage compartment medium temperature pan chiller and food prep surface The condensing systems are designed to be installed with minimal clearance to walls or other equipment These models are a...

Page 7: ...ge Hz Cycle Heaters freezers only Number of Heaters Total Amps Maximum Amp draw Minimum Circuit Minimum Circuit Ampacity Maximum Amps Protection Breaker size Refrigerant Refrigerant type and amount us...

Page 8: ...PLIED TO ENSURE EFFICIENT OPERATION AND EXTEND THE LIFE CYCLE OF YOUR EQUIPMENT 3 MAINTENANCE SCHEDULE DAILY WEEKLY BI WEEKLY MONTHLY CLEAN STORAGE CABINET X INSPECT GASKETS X CLEAN CONDENSING FILTER...

Page 9: ...ture is shown This parameter should be set to 35 0 which will reflect your temperature set point 2 If an adjustment needs to be made to the set temperature use the up arrow button 1 or the down arrow...

Page 10: ...quivalent to how often the unit will begin defrost mode every 2 hours 2 If an adjustment needs to be made use the up arrow button 1 or the down arrow button 3 to adjust the hour Press the set button 2...

Page 11: ...connection or a damaged temperature probe Please inspect both the connection and the temperature probe MANUAL DEFROST MODE If for any reason you need to initiate a Manual Defrost simply hold the down...

Page 12: ...this is set to 5 0 this is your refrigeration differential 2 If an adjustment needs to be made to the set temperature use the up arrow button 1 or the down arrow button 3 to adjust the temperature Pr...

Page 13: ...equivalent to how long the unit will be in defrost mode 45 minutes 2 If an adjustment needs to be made use the up arrow button 1 or the down ar row button 3 to adjust the hour Press and hold the set b...

Page 14: ...any reason your digital thermostat is displaying a flashing E0 it means that there is an error with the temperature probe 1 which is reading the freezer box temperature This is due to either a loose...

Page 15: ...Lift access panel up and pull outward to remove After removing the louvered panel remove the magnetic condenser filter by pulling the filter framing away from the condenser Louvered Panel Condenser F...

Page 16: ...revent premature failure of components NOTE CONDENSER COIL FINS SHOULD BE STRAIGHTEND IF NECESSARY TO ALLOW PROPER AIR CIRCULATION WARNING ANY SERVICE TO THE CONDENSING UNIT MUST BE PERFORMED BY AN AU...

Page 17: ...move REPLACING SNAP IN GASKETS Drawer gaskets are critical to maintaining the set temperature of your unit and should create a flush seal when the drawers are closed Defective gaskets can cause icing...

Page 18: ...asket by securely snapping lip of gasket into retaining strip of door on all sides Retaining Strip 4 Press gasket into retaining strip 5 Verify proper installation before re installing drawer 6 Re ins...

Page 19: ...e louvered panel in the compressor compartment Remove panel by lifting it up and pulling the bottom out Carefully clean dirt and lint from the condenser coil using a vacuum cleaner or soft brush Do no...

Page 20: ...annot be effectively cleaned and sanitized FULL DEFROST Each Chef s Base is designed to operate with a regularly scheduled automatic defrost feature but a monthly full manual defrost is required also...

Page 21: ...TH LET STAND 15 MINUTES OR MORE ACCORDING TO DIRECTIONS ON PACKAGE THEN RINSE DRY SATISFACTORY FOR USE ON ALL FINISHES HARD WATER SPOTS AND SCALE 5 OXALIC ACID 5 SULFAMIC ACID 5 TO 10 PHOSPHORIC ACID...

Page 22: ...harge unit to data place specifications 5 Thermostat controller refrigeration differential is not set properly 5 Verify refrigeration differential is set to 5 Refer to pgs 8 13 for thermostat controll...

Page 23: ...drawer handles Drawers are easily removed for cleaning Model Number Unit Width Inches mm Total Pans Drawers Width Configuration 14 3 8 356mm 22 3 8 566mm 27 1 4 692mm RB 36 SC FB 36 SC 36 914 A 2 RB...

Page 24: ...14 3 8 356mm 22 3 8 566mm 27 1 4 692mm RB 36 R FB 36 R 36 914 C 4 RB 48 R FB 48 R 48 1219 A B 6 RB 60 R FB 60 R 60 1524 B C 8 RB 72 R FB 72 R 72 1829 C 2 8 RB 84 R FB 84 R 84 2134 B 2 C 12 RB 96 R FB...

Page 25: ...SC FB 48 SC Qty 2 RB 48 R FB 48 R Qty 2 Qty 2 RB 60 SC FB 60 SC Qty 2 Qty 2 RB 60 R FB 60 R Qty 2 Qty 2 RB 72 SC FB 72 SC Qty 2 Qty 2 RB 72 R FB 72 R Qty 4 RB 84 SC FB 84 SC Qty 4 RB 84 R FB 84 R Qty...

Page 26: ...BLACK WIRING DIAGRAM RB SC R REFRIGERATED BASE SELF CONTAINED REMOTE 21...

Page 27: ...WIRING DIAGRAM FB SC R FREEZER BASE SELF CONTAINED REMOTE 22...

Page 28: ...COMPRESSOR COMPARTMENT EXPLODED VIEW 23...

Page 29: ...EVAPORATOR COIL 24...

Page 30: ...TOP DRAWER ASSEMBLY EXPLODED VIEW 25...

Page 31: ...BOTTOM DRAWER ASSEMBLY EXPLODED VIEW 26...

Page 32: ...with all local codes or in the absence of local codes with the current National Fuel Gas Code Z223 1 2 Installed under a properly designed and operating exhaust hood 3 Connected to the type of gas fo...

Page 33: ...__________________________________________ Model No _____________________________________________ Change No ____________________________________________ Name No of Part Model No Change No Serial No Th...

Reviews: