SERVICE
REFRIGERATION - MEDIUM TEMP
“REFRIGERATION DIFFERENTIAL” MODE
1. Hold down the
“set”
button (#2) for at least
five seconds until flashing
“ PS”
is shown.
Press the
“ up arrow”
button (#1) to reach the
flashing
“rd”
and press the
“set”
button (#2)
once. Make sure that this is set to
“5.0”
, this
your refrigeration differential.
2. If an adjustment needs to be made to the set
temperature, use the
“up arrow”
button (#1)
or the
“down arrow”
button (#3) to adjust the
temperature. Press the
“set”
button (#2) to
save your adjustment. Doing this will send
you back to the menu showing a flashing
“rd”
.
“DEFROST INTERVAL” MODE
1. Press the
“up arrow”
button (#1) to display
the
“dI”
parameter as shown and press the
“set”
button (#2) once. Make sure that
this is set to
“2”
, this is equivalent to how
often the unit will begin defrost mode (every
2 hours).
2. If an adjustment needs to be made use the
“up arrow”
button (#1) or the
“down arrow”
button (#3) to adjust the hour. Press the
“set”
button (#2) to save your adjustment. Doing this
will send you back to the hidden menu showing
a flashing
“dI”
.
“DEFROST PERIOD” MODE
1. Press the
“up arrow”
button (#1) to display
the
“dp”
parameter as shown and press the
“set”
button (#2) once. Make sure that
this is set to
“10”
, this is equivalent to how
long the unit will be in defrost mode (10
minutes).
2. If an adjustment needs to be made use the
“up arrow”
button (#1) or the
“down
arrow”
button (#3) to adjust the hour.
Press and hold the
“set”
button (#2) to save
your adjustment. Doing this will send you
back to operational mode.
“OFF” MODE
1. If for any reason your digital thermostat is
displaying a flashing
“Temperature/Off”
your
digital thermostat is in
“Off”
mode. To return
to the
“On”
mode, press and hold the
5
Summary of Contents for FB-108-R
Page 26: ...BLACK WIRING DIAGRAM RB SC R REFRIGERATED BASE SELF CONTAINED REMOTE 21...
Page 27: ...WIRING DIAGRAM FB SC R FREEZER BASE SELF CONTAINED REMOTE 22...
Page 28: ...COMPRESSOR COMPARTMENT EXPLODED VIEW 23...
Page 29: ...EVAPORATOR COIL 24...
Page 30: ...TOP DRAWER ASSEMBLY EXPLODED VIEW 25...