8
CONNECT ELECTRICAL
Verify that power is turned off at the source.
WARNING
If house wiring is not 2-wire with
a ground wire, a ground must be provided by the
installer. When house wiring is aluminum, be sure
to use U.L. approved anti-oxidant compound and
aluminum-to-copper connectors.
■ Remove junction box cover and knockout.
■ Use a conduit connector to secure the conduit to
the junction box.
■ Connect white leads to branch circuit white lead.
■ Connect black leads to branch circuit black lead.
■ Connect green/yellow leads to branch circuit green
lead or bare ground lead.
■ Secure all connections with wire nuts on each
electrical connector.
■ Push wires into junction box and replace cover. Be
sure wires are not pinched.
■ Secure electrical panel cover with original screws.
10
INSTALL FILTERS
■ Remove protective film on the filters.
NOTE:
It is not necessary to install the charcoal filter
in a vented installation.
■ Tip the filter into the slots at the rear of the opening.
Lift the filter lock and pull forward until the filter rests
in the slots.
■ Install both metal grease filters.
■ To remove the filters, press inwards on the handle
and pull the filter downwards.
9
INSTALL REAR MOUNTING
SCREWS
■ Pull the glass canopy forward to access and install
2 wood screws or fasteners through the bottom of
the hood and into the wall.
Install 2 Wood Screws
Filter Locks
1” = 2.5 cm; 1’ = 0.3 m