B.
Motor-Pump-Filter Assembly, PN3511-007 (refer to IPL Figure 2)
(1)
List of Materials
NOTE: Equivalent substitutes may be used for listed items.
(2)
Procedure
(a)
Apply a uniform film of sealant, EC 1239 (3M Co.) to periphery of the frame
assembly (195). Install mounting plate (215) on frame assembly, using screws
(200), washer (205), and nuts (210).
(b)
Install flapper (165) by pulling installation tail through hole in antisiphon housing
(140). Trim tail .010-.030 inch (0,25 to 0,76 mm) from bulb if new flapper is
being used.
(c)
Position retention washer in place on inlet tube (190) and install both with
gasket (180) on antisiphon housing (140), using washers (175), and nuts (170).
(d)
Install antisiphon housing (140), with gasket (160) on mounting plate (215),
using screws (145), washers (150), and nuts (155).
Lubricant
Lubriplate 105
Fiske Bros., Refining Co.
Newark, NJ 73219
Adhesive
3MNo. 1239
Minnesota Mining &
Manufacturing Co.
Adhesive Division
St. Paul, MN 55101
Lockwire
MS20995C32
Any government approved
source
Assembly Materials
Table 701
SOURCE
DESCRIPTION
ITEM