14
INSTALLATION, WIRING & PROGRAMMING
’UPGRADE‘ MODE PROGRAMMING
As standard, the M80II is programmed to operate from the supplied remote controls.
When inst
alled as an ‘upgrade’ the M80II is configured differently so it operates only from the vehicles
remote controls.
The Mongoose remotes are used for programming
– please leave them in the vehicle.
Changes in configuration are;
a.
The Automatic Engine Disable (AED) is off. Most vehicles have a factory immobiliser.
b.
Wire numbers 1-(Disarm#2), 4-(Arm) & 13-(Disarm) are enabled (they are disabled when
the M80II is used with the Mongoose remotes)
c.
Wire number 7
changes from ‘CH2 output’ to ‘Boot bypass’.
To change M80II to UPGRADE mode, change program No. 6 (AED) to OFF
Once programmed to ‘upgrade’ mode, the following 3 wires are enabled;
CONTROL INPUTS
Wire description
Function
ARM
Connect to
vehicle’s lock motor wire (Pulses positive when locked)
DISARM
Connect
to vehicle’s unlock motor wire (Pulses positive when unlocked)
DISARM #2
Programme #4
controls input
type
1)
LIGHT FLASH - Prog #4 ON (Default)
Connect
to vehicles positive Indicator flash wire
OR
2)
DISARM DEFEAT
- Prog #4 OFF
Connect to unlock signal wire from
driver’s door
(Pluses negative from key barrel when key is used)