34
83D0511
ILDV20/ILDV30 Fireplace Insert
MAiNteNANce
yeARLy SeRVice PROceDuRe
Failure to inspect and maintain heater may lead to improper combustion and a potentially dangerous
situation. A qualified technician should do the following once a year.
1. Check pilot flame. Flame should touch approximately 3/8" of the top of thermopile and touch top
of thermocouple.
Figure 38
If not, contact dealer for service.
. Turn gas control knob to “OFF” position to shut off gas to heater.
See step “To Turn Off Gas”, Page
27.
Let heater cool for 15 minutes. Remove faceplate (see instructions included with face plate)
and glass.
Page 29.
3. Carefully remove log set. If logs are severely deteriorated, replace logs. Check logs for sooting. A
small amount of soot along bottom of logs is normal. If excessive sooting is found, heater must be
adjusted. Contact dealer where you bought heater.
4. Clean burner and burner ports.
Figure 39
5. Replace log set and rock wool per instructions on Pages 1-3. Replace glass. Make sure gasket
along perimeter of glass contacts face of firebox and forms an airtight seal. Realign if airtight seal
is not formed. Replace glass and glass frame if damaged.
6. Inspect area behind face plate. Clean if necessary. Check gas control valve and all gas lines. If
damaged, do not use heater. Contact your dealer.
7. Start pilot and turn on main burner. Flames should be orange/yellow and not touch top of firebox.
If pilot or main burners do not burn correctly, contact your dealer for service. Monitor blower opera-
tion.
FP1943
pilot flame
Thermocouple
Thermopile
FP1943
Figure 38
Before taking unit apart, check
pilot flame. Flame should touch
thermocouple and thermopile.
FP1944
check burner ports
9/08
Check Burner Ports
FP1944
Figure 39
Check Burner Ports and Burners