0
83D0511
ILDV20/ILDV30 Fireplace Insert
eLectRicAL iNStALLAtiON
ReMOte WALL MOuNteD SWitch
A remote wall switch and up to fifteen (15) feet of 18 Ga. wire may be used with this appliance. At-
tach the wall switch in a junction box at the desired location on the wall.
Figure 15
.
NOte:
extended lengths of wire may cause the fireplace not to function properly. Longer
length of wire is permitted if the wire is made out of larger gauge (diameter) wire. Always
check with local code.
eLectRicAL WiRiNG
This insert will work without any electrical supply. Electricity is only needed to operate blower.
Verify proper operation after servicing.
W
ARN
iNG
electrical connections should only be performed by a qualified, licensed electrician.
Main power must be off when connecting to main electrical power supply or performing
service. All wiring shall be in compliance with all local, city and state codes. the appli-
ance, when installed, must be electrically grounded in accordance with local codes, or
in the absence of local codes, with the
National Electrical Code ANSI/NFPA 70 (latest
edition)
and
Canadian Electrical Code, CSA C22.1
.
Label all wires before disconnecting when
servicing controls. Wiring errors can cause
improper and dangerous operation.
c
A
uti
ON
PILOT
HI
LO
ON
OFF
FP1933
wall switch wiring
Figure 15
Wiring Diagram for Wall Switch
Sparker
Thermocouple
Piezo Igniter
Thermopile
Pilot Assembly
Switch
Millivolt
Valve
TH
TP
TH/TP
ON
OFF
Optional 15'
Wall Switch
Optional
Remote Control
ON
OFF
ON
OFF
hAND heLD ReMOte cONtROL
The remote control receiver may be installed in the control panel by removing
the ON/OFF switch and the knock-out plate. Slide the receiver into the space
where the knock-out plate was removed. Refer to remote instructions for wiring
and operation.
FP2177
remote receiver
Figure 15a
Remote Receiver
FP177
Remote
Receiver